■ Specifications and Test Methods
No Item
Specification
Test Method(Ref. Standard:JIS C 5101, IEC60384)
Shown in Rated value.
The rated voltage is defined as the maximum voltage which may be applied continuously to the capacitor.
When AC voltage is superimposed on DC voltage, V(peak to peak) or V(zero to peak),
whichever is larger, should be maintained within the rated voltage range.
1 Rated Voltage
No defects or abnormalities.
Shown in Dimension.
Visual inspection
2 Appearance
3 Dimension
Using Measuring instrument of dimension.
No defects or abnormalities.
Measurement Point
Test Voltage
Applied Time
Between the terminations
250% of the rated voltage
1s to 5s
4 Voltage proof
Charge/discharge current 50mA max.
Measurement Temperature
Measurement Point
Measurement Voltage
Charging Time
More than 500Ω・F
Room Temperature
Between the terminations
Rated Voltage
5 Insulation
Resistance(I.R.)
(Room Temperature)
2min
Charge/discharge current 50mA max.
Measurement Temperature
Shown in Rated value.
Room Temperature
6 Capacitance
Measurement Frequency 1.0+/-0.1kHz
Measurement Voltage
1.0+/-0.2Vrms
Measurement Temperature
DF≦0.025
Room Temperature
7 Q or Dissipation Factor
(D.F.)
Measurement Frequency 1.0+/-0.1kHz
Measurement Voltage 1.0+/-0.2Vrms
No bias
Applied voltage
Shown in Rated value.
Within +15/-40%(-55℃ to +125℃)
The capacitance change should be measured after 5 min at each specified temp. stage.
In case of applying voltage, the capacitance change should be measured after 1 min
with applying voltage in equilibration of each temp. stage.
8 Temperature
Characteristics of
Capacitance
Capacitance value as a reference is the value in "*" marked step.
Measurement Voltage
Pre-treatment
Less than 1.0Vrms (Refer to the individual data sheet)
Heat treatment:Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 24+/-2hours
at room temperature, then measure.
Temperature Step
GRM55MR11H334MA01-01C
2