■ Specifications and Test Methods
No Item
15 High Temperature High Appearance
Specification
Test Method(Ref. Standard:JIS C 5101, IEC60384)
No defects or abnormalities.
Within +/-12.5%
Mounting method
Pre-treatment
Solder the capacitor on the test substrate
Heat treatment:Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 24+/-2hours
at room temperature, then measure.
40+/-2℃
90%RH to 95%RH
500+/-12h
Humidity (Steady)
Capacitance Change
Q or D.F.
DF≦0.2
I.R.
More than 12.5Ω・F
Test Temperature
Test Humidity
Test Time
Test Voltage
Rated Voltage
Charge/discharge current 50mA max.
Post-treatment
Heat treatment:Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 24+/-2hours
at room temperature, then measure.
16 Durability
Appearance
Capacitance Change
Q or D.F.
No defects or abnormalities.
Within +/-12.5%
DF≦0.2
Mounting method
Pre-treatment
Solder the capacitor on the test substrate
Heat treatment:Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 24+/-2hours
at room temperature, then measure.
I.R.
More than 25Ω・F
Test Temperature
Test Time
Maximum Operating Temperature +/-3℃
1000+/-12h
Test Voltage
150% of the rated voltage
Charge/discharge current 50mA max.
Post-treatment
Heat treatment:Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 24+/-2hours
at room temperature, then measure.
GRM185B31A105KE35-01A
4