 浏览型号GRM1857U1H302JA44的Datasheet PDF文件第1页浏览型号GRM1857U1H302JA44的Datasheet PDF文件第3页浏览型号GRM1857U1H302JA44的Datasheet PDF文件第4页浏览型号GRM1857U1H302JA44的Datasheet PDF文件第5页浏览型号GRM1857U1H302JA44的Datasheet PDF文件第6页浏览型号GRM1857U1H302JA44的Datasheet PDF文件第7页浏览型号GRM1857U1H302JA44的Datasheet PDF文件第8页浏览型号GRM1857U1H302JA44的Datasheet PDF文件第9页  
Specifications and Test Methods  
Item  
Specification  
Test Method (Ref. Standard:JIS C 5101, IEC60384)  
No.  
1
Rated Voltage  
Shown in Rated value.  
The rated voltage is defined as the maximum voltage which may be applied continuously to the capacitor.  
When AC voltage is superimposed on DC voltage, VP-P or VO-P, whichever is larger, should be maintained  
within the rated voltage range.  
2
3
4
Appearance  
Dimension  
No defects or abnormalities.  
Shown in Rated value.  
Visual inspection.  
Using Measuring instrument of dimension.  
Voltage Proof  
No defects or abnormalities.  
Measurement Point :  
Test Voltage :  
Applied Time :  
Between the terminations  
300% of the rated voltage  
1s to 5s  
Charge/Discharge Current : 50mA max.  
5
6
Insulation Resistance(I.R.)  
More than 10000MΩ  
Shown in Rated value.  
Q1000  
Measurement Temperature:Room Temperature  
Measurement Point :  
Measurement Voltage :  
Charging Time :  
Between the terminations  
Rated Voltage  
2min  
Charge/Discharge Current : 50mA max.  
Capacitance  
Measurement Temperature:Room Temperature  
Measurement Frequency : 1.0+/-0.1kHz  
Measurement Voltage :  
1.0+/-0.2Vrms  
7
8
Q or Dissipation Factor (D.F.)  
Measurement Temperature : Room Temperature  
Measurement Frequency : 1.0+/-0.1kHz  
Measurement Voltage :  
1.0+/-0.2Vrms  
Nominal value of the temperature coefficient is shown in Rated value.  
Capacitance  
Temperature  
Characteristics  
No bias  
The capacitance change should be measured after 5 minutes at each specified temperature stage.  
But, the Capacitance Change under Reference Temperature is shown in  
Table A.  
Capacitance value as a reference is the value in "*" marked step.  
Capacitance Drift:Within +/-0.2% or +/-0.05pF (Whichever is larger)  
The capacitance drift is calculated by dividing the differences between the maximum and minimum measured values in the step 1,3 and 5 by the capacitance  
value in step 3.  
Measurement Voltage :  
Less than 1.0Vrms (Refer to the individual data sheet)  
Step  
1
Temperature(°C)  
Reference Temp. +/-2  
Applying Voltage  
2
Min. Operating Temp. +/-3  
Reference Temp. +/-2  
Max. Operating Temp. ±3  
Reference Temp. +/-2  
No bias  
3 *  
4
5