APPLICATION NOTES  
POWER SUPPLIES  
MULTIPLE CONVERTER SYNCHRONIZATION  
Synchronized operation of up to three BBF2800S series con-  
verters may be accomplished without external components. One  
unit selected to be the master is connected normally with pin  
10 grounded. The clock output pin 3 will provide the sync sig-  
nal for up to two slave units. The slave units have pin 10 not  
connected and receive the clock signal into pin 11. The clock  
signal lines may be shielded to prevent radiation. A separate 50  
ohm coax to each slave unit is recommended in order to pre-  
serve signal integrity. Shield ends should be connected to pin  
12 of the nearest converter.  
The output voltage of the BBF2800S may be adjusted from  
90% to 110% of nominal value by the use of a 50Kpotenti-  
ometer as shown. Adjustment beyond this range is possible  
however certain characteristics of the converter such as but  
not limited to input voltage range, efficiency, ripple and tem-  
perature performance will change. Characterization by the user  
is recommended in such applications.  
BBF2800S converters may also be synchronized to an exter-  
nal 500 KHz (+/- 5%) frequency source driving pin 11 of the  
converters.Pin10isnotconnected.Theconverterssynchronize  
to the positive edge of the frequency source allowing a variety  
of wave forms (pulse, square, spike) to be used. Pin 11 is  
internally capacitively coupled allowing unipolar or bipolar fre-  
quency sources to be used. The source should have a waveform  
risetimeof20nsorlessandbecapableofdrivingatleast4volts  
peak into each 50 ohm pin 11 input (50 volts peak max).  
An externally synchronized unit may be used to synchronize  
other (slave) units. The slave units may be used in turn to  
synchronize other slave units from their pin 3 outputs. Each  
“generationofslaveunitshasadelay(100-200nstypical)from  
the unit that it is synchronizing to.  
Adjust/comp (pin 4) may be driven by external circuitry refer-  
enced to pin 8 (-output sense) if desired. Grounding pin 4  
causes output voltage to increase (25% typically) while driving  
pin 4 above 1.3V causes output voltage to decrease. Pin 4  
may be driven through 10Kor more if connection of the comp  
function is also required.  
The comp function of pin 4 allows transient response and  
phase margin to be tailored to suit a specific application. This  
feature may be utilized by connecting a small (1-500nF) capaci-  
tor between pins 4 and 6 or 7. This is generally recommended  
when very large low ESR load capacitances are used.  
SHUTDOWN PLUS  
Pin 2 is used for remote shutdown, output fault detection,  
and/or setting the input voltage point at which the converter  
will turn on as shown in the typical application diagram. No  
connection to pin 2 is necessary for normal operation of the  
converter. Pin 2 is referenced to pin 12 (-input).  
Shutdown may be implemented by simply connecting pin 2  
to an open collector logic output or switch rated at 2.5mA,  
25Vdc or higher.  
Input voltage turn on point is programmed with a single resis-  
tor from pin 2 to 12. An input turn on/off hysteresis (typically  
3.5% of Vin) will be observed. This should be considered when  
making or verifying set point adjustment. The value of the  
setpoint resistor may be determined by the following:  
210·10³  
ETO-9.5  
R=  
(±10% accuracy at 25°C)  
Set point temperature coefficient is typically +400ppm/°C.  
Output fault monitoring is accomplished by observing pin 2 with  
a high impedance monitoring circuit. Pin 2 voltage drops from  
over 10V to below 1V when a load fault causes the converters  
fault protection circuitry to activate. It will remain low for at  
least 100mS and return high. If the load fault is still present pin  
2 will return low and the cycle will repeat. If there is no input  
setpoint programming resistor already in place a resistor  
>400Kfrom pin 2 to 12 will provide pin 2 pull down.  
7
Rev. F 12/06  