ELECTRICAL SPECIFICATIONS
BBF2803S
BBF2803S H/E
BBF2803S
Group A
Subgroup
Units
Test Conditions 1
Parameter
Typ.
Max.
Min.
Typ.
Max.
Min.
VDC
VDC
mA
mA
mVrms
mVrms
mArms
mArms
mV
mV
mV
mV
%
3.30
3.42
1
2,3
1
3.20
3.30
3.40
3.45
5500
5500
50
3.18
Output Voltage
-
-
3.15
-
-
-
-
5500
500
-
-
500
2
8
Output Current
16V≤VIN≤40V
BW=10KHz to 2MHz
BW=10KHz to 2MHz
VIN=16V to 40V
-
2,3
1
500
-
20
-
60
-
20
-
-
Output Voltage Ripple
Input Current Ripple 2
Line Regulation
-
2,3
1
-
60
-
20
-
60
-
20
-
50
-
-
2,3
1
-
60
-
±2
-
±25
-
±2
-
±20
±50
±15
±40
-
-
-
2,3
1
-
-
±1
-
±20
-
±1
-
-
Load Regulation
Efficiency
IOUT=0.5A to 5.5A
-
-
-
2,3
1
-
-
66
-
61
66
-
61
%
2,3
4
58
-
-
mV
mV
µS
IOUT=2.75A to/from 5.50A
Transition TIme=30µS
IOUT=2.75A to/from 5.50A
Transition TIme=30µS
VIN=16V to/from 40V
Transition Time=30µS
VIN=16V to/from 40V
Transition Time=30µS
±400 ±700
-
±400 ±600
-
2
Step Load Response
Step Load Recovery
Step Line Response
Step Line Recovery
Start Up Overshoot
-
100
-
-
220
-
5,6
4
-
-
100
-
±800
200
-
-
-
2
µS
5,6
4
-
300
-
mV
mV
µS
±500 ±800
-
±500 ±750
-
2
-
-
220
-
5,6
4
-
-
±1000
200
300
300
500
60
-
80
-
80
-
2
µS
-
5,6
4
-
-
-
mV
mV
mS
mS
µS
0
300
-
-
0
-
IOUT=5.5A
IOUT=5.5A
-
5,6
4
-
-
-
30
60
100
500
-
-
30
-
2
Start Up Delay
-
5,6
4
-
-
100
500
550
60
-
120
-
120
-
2
Shutdown Delay
µS
-
5,6
-
-
-
-
mS
V
2
20
60
40
40
-
Shutdown Recovery
Input Voltage Range
-
16
-
20
-
16
-
2
POUT=18W MAX.
-
1,2,3
1
-
40
mA
mA
mA
µF
35
35
40
Enabled, IOUT=0mA
Quiescent Current
-
2,3
1,2,3
1,2,3
1
-
-
50
-
Disabled IOUT=0mA
No Effect on DC Performance
1.25
2.5
300
-
-
1.25
2.5
300
-
-
Capacitive Load 2
Isolation
-
-
-
-
-
-
MΩ
A
Input to output or any pin to case @ 500V
100
5.5
475
±10
100
5.5
475
±10
Short Circuit Current Limit
Switching Frequency
7.8
500
-
8.5
525
-
7
1
7.8
500
-
8.5
525
-
KHz
%
4
VOUT Adjustment Range
RPOT=50KΩ
1
NOTES:
1 +VIN = 28V, IOUT = 5.5A, TA=TC=25°C unless otherwise specified.
2 Guaranteed by design but not tested. Typical parameters are representative of actual device performance but are for reference only.
3 Industrial grade and "E" suffix devices shall be tested to subgroups 1 and 4 unless otherwise specified.
4 Military grade devices ("H" suffix) shall be 100% tested to subgroups 1, 2, 3 and 4.
5 Subgroups 5 and 6 testing available upon request.
6 Subgroup 1, 4 TA=TC=+25°C
2, 5 TA=TC=+125°C
3, 6 TA=TC= -55°C
7 Device has internal shutdown feature that pulses the output with a low duty cycle during faults.
8 At case temperatures above 90°C, the BBF2803 requires VIN>16V to support a 5.5A load. At 125°C, 18V input is required
to support 5.5A output; 16V will support 4A output at 125°C.
3
Rev. F 12/06