MP2562 – 1A, 4MHz, 50V STEP-DOWN CONVERTER
ORDERING INFORMATION
Part Number
MP2562DQ*
MP2562DS**
Package
3x3 QFN10
SOIC8
Top Marking
9F
Free Air Temperature (TA)
–40C to +85C
MP2562DS
–40C to +85C
* For Tape & Reel, add suffix –Z (e.g. MP2562DQ–Z) .
For RoHS Compliant Packaging, add suffix –LF (e.g. MP2562DQ–LF–Z)
** For Tape & Reel, add suffix –Z (e.g. MP2562DS–Z) .
For RoHS Compliant Packaging, add suffix –LF (e.g. MP2562DS–LF–Z)
PACKAGE REFERENCE
TOP VIEW
TOP VIEW
SW
SW
1
2
3
4
5
10 BST
9
8
7
6
VIN
SW
EN
1
2
3
4
8
7
6
5
BST
EN
VIN
VIN
COMP
FB
FREQ
GND
COMP
FB
FREQ
GND
EXPOSED PAD
ON BACKSIDE
CONNECT TO GND
QFN10
SOIC8
ABSOLUTE MAXIMUM RATINGS (1)
Supply Voltage (VIN).....................–0.3V to +55V
Switch Voltage (VSW)...........................................
................-0.3V (-5V for <10ns) to VIN +0.3V
BST to SW.....................................–0.3V to +6V
All Other Pins.................................–0.3V to +6V
Continuous Power Dissipation. ….(TA=+25C) (2)
3x3 QFN10……………………………….….2.5W
SOIC8………………………….……………..1.3W
Junction Temperature...............................150C
Lead Temperature ....................................260C
Storage Temperature................. –65°C to +150
Thermal Resistance (4)
3x3 QFN10 .............................50...... 12... C/W
SOIC8.....................................96...... 45... C/W
θJA
θJC
Notes:
1) Exceeding these ratings may damage the device.
2) The maximum allowable power dissipation is a function of the
maximum junction temperature TJ(MAX), the junction-to-
ambient thermal resistance θJA, and the ambient temperature
TA. The maximum allowable continuous power dissipation at
any ambient temperature is calculated by PD(MAX)=(TJ(MAX)-
TA)/ θJA. Exceeding the maximum allowable power dissipation
will cause excessive die temperature, and the regulator will go
into thermal shutdown. Internal thermal shutdown circuitry
protects the device from permanent damage..
3) The device is not guaranteed to function outside of its
operating conditions.
4) Measured on JESD51-7 4-layer board.
Recommended Operating Conditions (3)
Supply Voltage VIN ...........................4.5V to 50V
Output Voltage VOUT.........................0.8V to 47V
Operating Junct. Temp. .......... –40C to +125C
MP2562 Rev. 1.0
2/28/2014
www.MonolithicPower.com
MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited.
© 2014 MPS. All Rights Reserved.
2