MP1482 – 2A, 18V SYNCHRONOUS RECTIFIED, STEP-DOWN CONVERTER
PIN FUNCTIONS
SOIC8
Name Description
Pin #
1
2
High-Side Gate Drive Boost Input. BS supplies the drive for the high-side N-Channel MOSFET
switch. Connect a 0.01μF or greater capacitor from SW to BS to power the high side switch.
Power Input. IN supplies the power to the IC, as well as the step-down converter switches.
IN
Drive IN with a 4.75V to 18V power source. Bypass IN to GND with a suitably large capacitor to
eliminate noise on the input to the IC. See
Input Capacitor.
Power Switching Output. SW is the switching node that supplies power to the output. Connect
SW the output LC filter from SW to the output load. Note that a capacitor is required from SW to BS
to power the high-side switch.
GND Ground.
Feedback Input. FB senses the output voltage to regulate that voltage. Drive FB with a resistive
FB
voltage divider from the output voltage. The feedback threshold is 0.923V. See
Setting the
Output Voltage.
Compensation Node. COMP is used to compensate the regulation control loop. Connect a
series RC network from COMP to GND to compensate the regulation control loop. In some
COMP
cases, an additional capacitor from COMP to GND is required. See
Compensation
Components.
Enable Input. EN is a digital input that turns the regulator on or off. Drive EN high to turn on the
EN
regulator, drive it low to turn it off. Pull up with 100kΩ resistor for automatic startup.
Soft-Start Control Input. SS controls the soft start period. Connect a capacitor from SS to GND
SS
to set the soft-start period. A 0.1μF capacitor sets the soft-start period to 15ms. To disable the
soft-start feature, leave SS unconnected.
BS
3
4
5
6
7
8
MP1482 Rev. 1.31