 浏览型号XPC855TCZP50D4的Datasheet PDF文件第8页浏览型号XPC855TCZP50D4的Datasheet PDF文件第9页浏览型号XPC855TCZP50D4的Datasheet PDF文件第10页浏览型号XPC855TCZP50D4的Datasheet PDF文件第11页浏览型号XPC855TCZP50D4的Datasheet PDF文件第13页浏览型号XPC855TCZP50D4的Datasheet PDF文件第14页浏览型号XPC855TCZP50D4的Datasheet PDF文件第15页浏览型号XPC855TCZP50D4的Datasheet PDF文件第16页  
Estimation Using Simulation  
If the board temperature is known, an estimate of the junction temperature in the  
environment can be made using the following equation:  
TJ = TB + (RθJB × PD)  
where:  
RθJB = junction-to-board thermal resistance (ºC/W)  
TB = board temperature (ºC)  
PD = power dissipation in package  
If the board temperature is known and the heat loss from the package case to the air can be  
ignored, acceptable predictions of junction temperature can be made. For this method to  
work, the board and board mounting must be similar to the test board used to determine the  
junction-to-board thermal resistance, namely a 2s2p (board with a power and a ground  
plane) and vias attaching the thermal balls to the ground plane.  
7.4 Estimation Using Simulation  
When the board temperature is not known, a thermal simulation of the application is  
needed. The simple two resistor model can be used with the thermal simulation of the  
application [2], or a more accurate and complex model of the package can be used in the  
thermal simulation.  
7.5 Experimental Determination  
To determine the junction temperature of the device in the application after prototypes are  
available, the thermal characterization parameter (ΨJT) can be used to determine the  
junction temperature with a measurement of the temperature at the top center of the  
package case using the following equation:  
TJ = TT + (ΨJT × PD)  
where:  
ΨJT = thermal characterization parameter  
TT = thermocouple temperature on top of package  
PD = power dissipation in package  
The thermal characterization parameter is measured per JEDEC JESD51-2 specification  
using a 40 gauge type T thermocouple epoxied to the top center of the package case. The  
thermocouple should be positioned so that the thermocouple junction rests on the package.  
A small amount of epoxy is placed over the thermocouple junction and over about 1 mm of  
wire extending from the junction. The thermocouple wire is placed flat against the package  
case to avoid measurement errors caused by cooling effects of the thermocouple wire.  