 浏览型号XC68HC912D60FU8的Datasheet PDF文件第154页浏览型号XC68HC912D60FU8的Datasheet PDF文件第155页浏览型号XC68HC912D60FU8的Datasheet PDF文件第156页浏览型号XC68HC912D60FU8的Datasheet PDF文件第157页浏览型号XC68HC912D60FU8的Datasheet PDF文件第159页浏览型号XC68HC912D60FU8的Datasheet PDF文件第160页浏览型号XC68HC912D60FU8的Datasheet PDF文件第161页浏览型号XC68HC912D60FU8的Datasheet PDF文件第162页  
Freescale Semiconductor, Inc.  
Clock Functions  
12.6.8 Pseudo-STOP  
Pseudo-STOP is a low power mode similar to STOP where the external  
oscillator is allowed to run (at reduced amplitude) whilst the rest of the  
part is in STOP. This increases the current consumption over STOP  
mode by the amount of current in the oscillator, but reduces wear and  
mechanical stress on the crystal.  
If the PSTP bit in the PLLCR register is set, the MCU goes into Pseudo-  
STOP mode when a STOP instruction is executed.  
Pseudo-STOP mode is exited the same as STOP with an external reset,  
an external interrupt from IRQ or XIRQ, a Key Wake-Up interrupt from  
port J or port H, or an MSCAN Wake-Up interrupt.  
The effect of the DLY bit is the same as noted above in STOP Exit and  
Fast STOP Recovery.  
12.6.9 Pseudo-STOP exit in Limp Home mode with Delay  
(NOLHM=0, CME=X, DLY=1)  
When coming out of Pseudo-STOP mode with the NOLHM bit cleared  
and the DLY bit set, the MCU goes into limp-home mode (regardless of  
the state of the CME or FCME bits).  
The VCO supplies the limp-home clock frequency to the 13-stage  
counter (XCLK). The BCSP output is forced high and MCS is forced low.  
After the 13-stage counter reaches a count of 4096 XCLK cycles, a  
check of the clock monitor is performed and as the crystal oscillator was  
kept running due to the Pseudo-stop mode, the MCU exits STOP  
normally, using the EXTALi clock. In the case where a crystal failure  
occurred during pseudo-stop, then the MCU exits STOP using the limp  
home clock (f  
) with both the LHOME flag set and the LHIF limp-  
VCOMIN  
home interrupt request set to indicate it is not operating at the desired  
frequency. Each time the 13-stage counter reaches a count of 4096  
XCLK cycles, a check of the clock monitor is performed. If the clock  
monitor indicates the presence of an external clock, limp-home mode is  
de-asserted, the LHOME flag is cleared and the LHIF limp-home  
Advance Information  
158  
68HC(9)12D60 — Rev 4.0  
Clock Functions  
MOTOROLA  
For More Information On This Product,  
Go to: www.freescale.com  
 复制成功!