V436632Y24V
Sym-
bol
I
CC
1
CILETIV LESO M
Standby and Refresh Currents
1
T
A
= 0°C to 70°C, V
CC
= 3.3V
±
0.3V
Parameter
Operating Current
Test Conditions
Burst length = 4, CL = 3
t
RC
> = t
RC
(min),
t
CK
> = t
CK
(min), IO = 0 mA
2 Bank Interleave Operation
CKE< = V
IL
(max), t
CK
> = t
CK
(min)
CKE> = V
IH
(min), t
CK
> = t
CK
(min), In-
put changed once in 3 cycles
75PC/75
920
10PC
680
Unit
mA
Note
1,2
I
CC
2P
I
CC
2N
Precharged Standby Current in
Power Down Mode
Precharged Standby Current in
Non-Power Down Mode
16
16
mA
160
120
mA
CS = High
I
CC
3P
I
CC
3N
I
CC
4
Active Standby Current in Power
Down Mode
CKE< = V
IL
(max), t
CK
> = t
CK
(min)
80
80
mA
Active Standby Current in Non-Pow- CKE> = V
IH
(min), t
CK
> = t
CK
(min), In-
er Down Mode
put changed one time
Burst Operating Current
Burst length = Full Page,
t
RC
= Infinite, CL = 3,
t
CK
> = t
CK
(min), IO = 0 mA
2 Banks Activated
t
RC
>= t
RC
(min)
CKE = <0.2 V
Standard
L-Version
200
180
mA
CS = High
600
400
mA
1, 2
I
CC
5
I
CC
6
Auto Refresh Current
Self Refresh Current
1920
24
13.6
1760
24
13.6
mA
mA
1,2
1,2
V436632Y24V Rev. 1.2 March 2002
7