PUMA 2E1000-70/90/12
ISSUE 4.2 : November 1998
Package Details Dimensions in mm (inches).
27.69 (1.090) Sq. Max.
4.83 (0.190)
2.54 (0.100) typ.
15.24 (0.60) typ
4.32 (0.170)
0.53 (0.021)
0.38 (0.015)
1.40 (0.055)
1.14 (0.045)
2.54 (0.100) typ.
1.27 (0.050)
0.64 (0.025)
1.52 (0.060)
1.02 (0.040)
8.13 (0.320) max
Military Screening Procedure
Module Screening Flow for high reliability product is in accordance with MIL-STD-883 method 5004 Level B and
is detailed below:
MB MODULE SCREENING FLOW
SCREEN
TEST METHOD
LEVEL
Visual and Mechanical
External visual
Temperature cycle
2017 Condition B (or manufacturers equivalent)
1010 Condition C (10 Cycles,-65°C to +150°C)
100%
100%
Burn-In
Pre Burn-in Electrical
Burn-In
Per Applicable device Specifications at TA = +25°C (optional) 100%
Method 1015, Condition D, TA = +125°C
100%
Final Electrical Tests
Per applicable Device Specification
Static (dc)
a) @ TA=+25°C and power supply extremes
b) @ temperature and power supply extremes
100%
100%
Functional
a) @ TA=+25°C and power supply extremes
b) @ temperature and power supply extremes
100%
100%
Switching (ac)
a) @ TA=+25°C and power supply extremes
b) @ temperature and power supply extremes
100%
100%
Percent Defective Allowable (PDA)
Quality Conformance
Calculated at Post Burn-in at TA=+25°C
Per applicable Device Specification
2009 Per HMP or customer specification
10%
Sample
External Visual
11