 浏览型号PUMA2E1000LM-90的Datasheet PDF文件第4页浏览型号PUMA2E1000LM-90的Datasheet PDF文件第5页浏览型号PUMA2E1000LM-90的Datasheet PDF文件第6页浏览型号PUMA2E1000LM-90的Datasheet PDF文件第7页浏览型号PUMA2E1000LM-90的Datasheet PDF文件第8页浏览型号PUMA2E1000LM-90的Datasheet PDF文件第9页浏览型号PUMA2E1000LM-90的Datasheet PDF文件第11页浏览型号PUMA2E1000LM-90的Datasheet PDF文件第12页  
ISSUE 4.2 : November 1998  
PUMA 2E1000-70/90/12  
Software Data Protection  
Softwarecontrolleddataprotection,onceenabled by theuser,necessitatestheuseofasoftwarealgorithmbefore  
any Write can be performed. To enable this feature a special sequence of 3 Writes to 3 specific addresses must  
be performed, and must be reused for each subsequent Write cycle. Once set the data protection remains  
operational until it is disabled by using a second algorithm; power transitions will not reset this feature.  
Note that the PUMA 2E1000 is supplied with the Software data Protection feature disabled.  
The algorithms to enable and disable the protection are shown below:  
SDP Enable  
SDP Disable  
LOAD DATA AA  
TO  
LOAD DATA AA  
TO  
ADDRESS 5555  
ADDRESS 5555  
LOAD DATA 55  
TO  
LOAD DATA 55  
TO  
ADDRESS 2AAA  
ADDRESS 2AAA  
LOAD DATA A0  
TO  
LOAD DATA 80  
TO  
ADDRESS 5555  
ADDRESS 5555  
WRITES  
ENABLED  
(2)  
LOAD DATA AA  
TO  
ADDRESS 5555  
LOAD DATA XX  
TO  
ANY ADDRESS  
(4)  
LOAD DATA 55  
TO  
ADDRESS2AAA  
LOAD LAST BYTE/  
WORD TO  
LAST ADDRESS  
ENTER DATA  
PROTECT  
STATE  
LOAD DATA 20  
TO  
ADDRESS 5555  
Once initiated, the enable sequence of  
write operations should not be interrupted  
EXIT DATA  
PROTECT  
STATE  
(3)  
LOAD DATA XX  
TO  
ANY ADDRESS  
(4)  
Notes : (1) Data D7 - D0 (hex); Address A14 - A0 (hex).  
(2) Write Protect Mode will be activated at end of  
Write even if no other data is loaded.  
LOAD LAST BYTE/  
WORD TO  
LAST ADDRESS  
(3) Write protect state will be disabled at end of  
write period even if no other data is loaded.  
(4) 1 to 64 bytes/words of data can be loaded.  
Note: Load Data above represents 8 bit mode. For 16 or 32 bit mode, place the load data in the 2 bytes or  
all 4 bytes on the data lines, respectively. Eg/ 8 bit load data = 55HEX, 16 bit load data = 5555HEX  
.
All software write commands must obey the Page Write timing specifications.  
TheprocessofdisablingtheDataProtectionmodeisverysimilartothatdescribedforenable,except6bytes/words  
must be loaded to specific locations in the EEPROM as shown.  
Noteheretheuseoftheword'load'todescribeenablinganddisablingtheprotectionmodesinpreferenceto'write'.  
Although it may seem that if the Write command sequence is performed to enable protection then the three bytes/  
words at those addresses will be overwritten with AA,55,A0, this is not the case.  
10