ISO-CMOS MT8952B  
FIFO are flagged with two status bits. The status  
bits are found in the FIFO status register and  
indicate whether the byte to be read from the FIFO is  
the first byte of the packet, the middle of the packet,  
the last byte of the packet with good FCS or the last  
byte of the packet with bad FCS. This status  
indication is valid for the byte to be read from the  
receive FIFO.  
clocked into the receive FIFO and tagged as having  
bad FCS.  
Frame Abort:  
When a frame abort is received the appropriate bits  
in the Interrupt Flag and Status Registers are set.  
The last byte of the packet that was aborted is  
written to the FIFO with a status of ‘packet byte’  
tagged to it. The CPU determines which packet in  
the FIFO was aborted, if there is more than one  
packet in the FIFO, by the absence of ‘last byte’  
status on any of the bytes.  
The incoming data is always written to the FIFO in a  
bytewide manner. However, in the event of data sent  
not being a multiple of eight bits, the software  
associated with the receiver should be able to pick  
the data bits from the MSB positions of the last byte  
in the received data written to the FIFO. The  
Protocol Controller does not provide any indication  
as to how many bits this might be.  
Idle Channel:  
While receiving the idle channel, the idle bit in the  
general status register remains set.  
Go Ahead:  
Receive FIFO Empty:  
The occurrence of this sequence can be used to  
generate an interrupt as described earlier. The  
receive circuitry will not recognize a frame abort  
followed by a flag as go ahead.  
When the Receive FIFO is empty, this state is  
indicated by the Receive FIFO status bits in the FIFO  
Status Register. As with the Tx FIFO status bits (see  
Transmit FIFO Full Section), these bits are not  
updated for two bit periods after any access of the  
Receive FIFO. If the controlling microprocessor’s  
bus cycle is much shorter than a bit period on the  
serial port, then the status bits may not be updated  
to indicate there is no information left in the Rx FIFO  
before the microprocessor has returned to read the  
Rx FIFO again. The result is an underflow condition  
that is only evident by redundant bytes in the  
received message.  
C-Channel Reception:  
The information contained in channel-1 of the  
incoming ST-BUS (CDSTi) is shifted into the C-  
Channel Status Register during the Internal Timing  
Mode.  
Transparent Data Transfer:  
By setting the IFTF bits in the Control Register to  
select the transparent data transfer, the receive  
section can be made to disable the protocol  
functions like Flag/Abort/GA/Idle detection, zero  
deletion, CRC calculation and address comparison.  
The received data is shifted in from CDSTi and  
written to receive FIFO in bytewide format. If the  
Protocol Controller is in the Internal Timing Mode  
and the Timing Control bits are set to 2, 6 or 7 bits/  
frame, the respective MSBs of each byte are only to  
be read from the data bus. The transparent data  
transfer facility is not available when the Timing  
Control bits are set to one bit/frame. The receive  
section can be disabled in software immediately  
using the RxEN bit in the Control Register.  
To avoid a Rx FIFO underflow, reading information  
from the Rx FIFO should be approached in two  
ways. The first approach is to be used when the  
MT8952B indicates (via interrupt) that the Rx FIFO  
is 15/19 FULL. The controlling microprocessor  
should then immediately read 14 bytes from the Rx  
FIFO. This will avoid emptying the FIFO. The  
second approach is to be used when an End of  
Packet interrupt is signalled by the MT8952B. The  
controlling microprocessor should then empty the Rx  
FIFO until the Rx Byte Status bits in the FIFO Status  
Register indicate that the byte about to be read is the  
last byte. These bits are “tag“ bits whose state was  
determined before the End of Packet condition was  
indicated, therefore their state is valid.  
The operation of the receiver is similar in the  
External Timing Mode.  
Invalid Packets:  
If there are less than 24 data bits between the  
opening and closing flags, the packet is considered  
invalid and the data never enters the receive FIFO.  
This is true even with data and the abort sequence,  
the total of which is less than 24 bits. The data  
packets that are at least 24 bits but less than 32 bits  
long are also invalid, but not ignored. They are  
Receive Overflow:  
Receive overflow occurs when the receive section  
attempts to load a byte to an already full receive  
FIFO. This status can be used to generate the  
interrupt as described earlier.  
3-73