欢迎访问ic37.com |
会员登录 免费注册
发布采购

MKW2626 参数 Datasheet PDF下载

MKW2626图片预览
型号: MKW2626
PDF下载: 下载PDF文件 查看货源
内容描述: 15W ,超宽输入范围,单和双输出DC / DC转换器 [15W, Ultra-Wide Input Range, Single & Dual Output DC/DC Converters]
分类和应用: 转换器
文件页数/大小: 8 页 / 240 K
品牌: MINMAX [ MINMAX TECHNOLOGY CO., LTD. ]
 浏览型号MKW2626的Datasheet PDF文件第1页浏览型号MKW2626的Datasheet PDF文件第2页浏览型号MKW2626的Datasheet PDF文件第3页浏览型号MKW2626的Datasheet PDF文件第4页浏览型号MKW2626的Datasheet PDF文件第5页浏览型号MKW2626的Datasheet PDF文件第7页浏览型号MKW2626的Datasheet PDF文件第8页  
MKW2600 Series  
Test Configurations  
Overcurrent Protection  
To provide protection in a fault (output overload) condition,  
the unit is equipped with internal current limiting circuitry and  
can endure current limiting for an unlimited duration. At the  
point of current-limit inception, the unit shifts from voltage  
control to current control. The unit operates normally once the  
output current is brought back into its specified range.  
Input Reflected-Ripple Current Test Setup  
Input reflected-ripple current is measured with a inductor  
Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to  
simulate source impedance.  
Capacitor Cin, offsets possible battery impedance .  
Current ripple is measured at the input terminals of the  
module, measurement bandwidth is 0-500 KHz.  
Input Source Impedance  
The power module should be connected to a low  
ac-impedance input source. Highly inductive source  
impedances can affect the stability of the power module.  
In applications where power is supplied over long lines and  
output loading is high, it may be necessary to use a capacitor  
at the input to ensure startup.  
To Oscilloscope  
+Vin  
+Out  
+
+
Lin  
DC / DC  
Converter  
Current  
Probe  
Load  
Battery  
Cin  
-Vin  
-Out  
Capacitor mounted close to the power module helps  
ensure stability of the unit, it is recommended to use a good  
quality low Equivalent Series Resistance (ESR < 1.0[ at 100  
KHz) capacitor of a 10uF for the 24V and 48V input devices.  
Peak-to-Peak Output Noise Measurement Test  
Use a Cout 0.47uF ceramic capacitor.  
Scope measurement should be made by using a BNC  
socket, measurement bandwidth is 0-20 MHz. Position the  
load between 50 mm and 75 mm from the DC/DC Converter.  
+
+Vin  
DC / DC  
+Out  
-Out  
+
DC Power  
Source  
+Vin  
+Out  
Copper Strip  
Cout  
Load  
Converter  
Cin  
Single Output  
DC / DC  
Resistive  
Load  
-
-Vin  
Scope  
Converter  
-Vin  
-Out  
Copper Strip  
Cout  
+Vin  
+Out  
Com.  
-Out  
Scope  
Scope  
Dual Output  
DC / DC  
Resistive  
Load  
Converter  
Cout  
-Vin  
Design & Feature Considerations  
Remote On/Off  
Positive logic remote on/off turns the module on during a  
logic high voltage on the remote on/off pin, and off during a  
logic low.  
To turn the power module on and off, the user must supply  
a switch to control the voltage between the on/off terminal and  
the -Vin terminal.  
The switch can be an open collector or equivalent.  
A logic low is -0.7V to 0.8V.  
A logic high is 2.5V to 5.5V.  
The maximum sink current at on/off terminal during a logic  
low is -1 mA.  
The maximum allowable leakage current of the switch at  
on/off terminal (2.5 to 5.5V) is 50uA.  
REV:0 2005/04  
MINMAX  
6
 复制成功!