欢迎访问ic37.com |
会员登录 免费注册
发布采购

MKW2626 参数 Datasheet PDF下载

MKW2626图片预览
型号: MKW2626
PDF下载: 下载PDF文件 查看货源
内容描述: 15W ,超宽输入范围,单和双输出DC / DC转换器 [15W, Ultra-Wide Input Range, Single & Dual Output DC/DC Converters]
分类和应用: 转换器
文件页数/大小: 8 页 / 240 K
品牌: MINMAX [ MINMAX TECHNOLOGY CO., LTD. ]
 浏览型号MKW2626的Datasheet PDF文件第1页浏览型号MKW2626的Datasheet PDF文件第3页浏览型号MKW2626的Datasheet PDF文件第4页浏览型号MKW2626的Datasheet PDF文件第5页浏览型号MKW2626的Datasheet PDF文件第6页浏览型号MKW2626的Datasheet PDF文件第7页浏览型号MKW2626的Datasheet PDF文件第8页  
MKW2600 Series  
Model Selection Guide  
Reflected  
Model  
Input  
Voltage  
Output  
Voltage  
Output Current  
Input Current  
Efficiency  
Ripple  
Number  
Current  
Max.  
mA  
Min.  
mA  
300  
@Max. Load @No Load  
mA (Typ.) mA (Typ.) mA (Typ.)  
@Max. Load  
% (Typ.)  
78  
VDC  
VDC  
3.3  
5
MKW2621  
MKW2622  
MKW2623  
MKW2624  
MKW2625  
MKW2626  
MKW2627  
MKW2629  
MKW2631  
MKW2632  
MKW2633  
MKW2634  
MKW2635  
MKW2636  
MKW2637  
MKW2639  
3000  
3000  
1250  
1000  
1500  
{625  
{500  
3000  
3000  
3000  
1250  
1000  
1500  
{625  
{500  
3000  
528  
762  
735  
726  
300  
82  
12  
125  
85  
15  
100  
86  
24  
25  
40  
( 9 ~ 36 )  
{5  
{12  
{15  
5.1  
3.3  
5
150  
771  
735  
726  
787  
264  
381  
368  
363  
386  
368  
363  
393  
81  
{62.5  
{50  
300  
85  
86  
81  
300  
78  
300  
82  
12  
125  
85  
15  
100  
86  
48  
15  
30  
( 18 ~ 75 )  
{5  
{12  
{15  
5.1  
150  
81  
{62.5  
{50  
300  
85  
86  
81  
Notes :  
Absolute Maximum Ratings  
1. Specifications typical at Ta=+25], resistive load,  
nominal input voltage, rated output current unless  
otherwise noted.  
Parameter  
Min.  
Max.  
50  
Unit  
24VDC Input Models  
48VDC Input Models  
-0.7  
-0.7  
---  
---  
VDC  
VDC  
]
Input Surge Voltage  
( 1000 mS )  
2. Transient recovery time is measured to within 1%  
error band for a step change in output load of 75%  
to 100%.  
100  
Lead Temperature (1.5mm from case for 10 Sec.)  
Internal Power Dissipation  
260  
5,000  
mW  
3. Ripple & Noise measurement bandwidth is 0-20  
MHz.  
Exceeding the absolute maximum ratings of the unit could cause damage.  
These are not continuous operating ratings.  
4. These power converters require a minimum output  
loading to maintain specified regulation.  
5. Operation under no-load conditions will not damage  
these modules; however, they may not meet all  
specifications listed.  
6. All DC/DC converters should be externally fused at  
the front end for protection.  
Environmental Specifications  
7. Other input and output voltage may be available,  
please contact factory.  
Parameter  
Operating Temperature  
Operating Temperature  
Storage Temperature  
Humidity  
Conditions  
Ambient  
Case  
Min.  
-40  
-40  
-50  
---  
Max.  
+60  
+100  
+125  
95  
Unit  
]
]
]
%
8. To order the converter with Remote On/Off function,  
please add a suffix -RC (e.g. MKW2621-RC).  
9. To order the converter with EN55022 Class A  
function, please add a suffix A (e.g. MKW2621A).  
10. Specifications subject to change without notice.  
Cooling  
Free-Air Convection  
Six-Sided Shielded, Metal Case  
EN55022 Class A  
RFI  
Conducted EMI  
REV:0 2005/04  
MINMAX  
2