PRODUCT DATABOOK 1996/1997
MC33164/MC34164
5V U
N D E RV O LTAGE
S
ENSING
C
I R C U I T
P
R O D U C T I O N
D
A T A
S
H E E T
R E C O M M E N D E D O P E R AT I N G C O N D I T I O N S
Parameter
Input Supply Voltage
RESET Output Voltage
Clamp Diode Forward Current
Operating Ambient Temperature Range:
MC34164
MC33164
Note 2. Range over which the device is guaranteed functional.
(Note 2)
Symbol
Recommended Operating Conditions
Min.
Typ.
Max.
1
10
10
50
70
85
Units
V
V
mA
°C
°C
T
A
T
A
0
-40
ELECTRICAL CHARACTERISTICS
(Unless otherwise specified, these specifications apply over the operating ambient temperatures of 0°C
≤
T
A
≤
70°C for the MC34164 and -40°C
≤
T
A
≤
85°C
for the MC33164. Low duty cycle pulse testing techniques are used which maintains junction and case temperatures equal to the ambient temperature.)
Parameter
Total Device
Operating Input Voltage Range
Quiescent Input Current
Symbol
Test Conditions
MC33164 / MC34164
Min. Typ.
Max.
1.0
10
20
50
Units
V
IN
I
IN
V
IN
= 5.0V
V
IN
= 10V
10
19
V
µA
µA
Comparator Section
Threshold Voltage
High-State Output
Low-State Output
Hysteresis
V
IH
V
IL
V
H
V
OL
I
SINK
V
IN
Increasing
V
IN
Decreasing
4.15
4.15
0.02
4.33
4.27
0.06
0.05
0.06
7.0
4.45
4.45
V
V
V
V
V
mA
µA
µA
V
RESET
Output Section
Output Sink Saturation
Output Sink Current
Output Off-State Leakage
Clamp Diode Forward Voltage
V
IN
= 4.0V, I
SINK
= 1.0mA
V
IN
= 1.0V, I
SINK
= 0.25mA
V
IN
, RESET = 4.0V
V
IN
, RESET = 5.0V
V
IN
, RESET = 10V
Pin 1 to pin 2, (I
F
= 5.0mA)
0.40
0.30
50
0.5
2.0
1.2
V
F
0.6
Copyright © 1997
Rev. 1.5 11/97
3