PRELIMINARY DATA SHEET
VDP 31xxB
3.2.1. Scaler Adjustment
In case of linear scaling, most of the scaler registers
need not be set. Only the scaler mode, active video
length, and the fixed scaler increments (scinc1/scinc2)
must be written.
The adjustment of the scaler for nonlinear scaling
modes should use the parameters given in Table 3–4.
Table 3–4: Set-up values for nonlinear scaler modes
Register
Scaler Modes
‘waterglass’
border 35%
‘panorama’
border 30%
center compression
3/4
1643
1024
90
5/6
4/3
1024
376
85
6/5
1024
611
56
scinc1
1427
1024
56
scinc2
scinc
fflim
945
110
156
317
363
473
110
156
384
430
540
985
115
166
327
378
493
115
166
374
425
540
921
83
983
94
scw1 – 0
scw1 – 1
scw1 – 2
scw1 – 3
scw1 – 4
scw2 – 0
scw2 – 1
scw2 – 2
scw2 – 3
scw2 – 4
147
314
378
461
122
186
354
418
540
153
339
398
492
118
177
363
422
540
Micronas