ADVANCE INFORMATION
VDP 313xY
3.6. Electrical Characteristics
3.6.1. Absolute Maximum Ratings
Symbol
TJ
Parameter
Pin Name
Min.
0
Max.
Unit
°C
°C
mW
V
Junction Temperature
Storage Temperature
Total Power Dissipation
Supply Voltage
125
TS
−40
−
125
PTOT
VSUPx
VI
1400
VSUPx
−0.3
−0.3
−0.3
−0.3
6
Input Voltage, all Inputs
Output Voltage, all Outputs
VSUPx+0.31)
VSUPx+0.31)
6
V
VO
V
VIO
Input/Output Voltage, all Open
Drain Outputs
V
VES
Electrostatic Handling, HBM 2)
−2000
+2000
V
1) Refer to Pin Circuits (chapter 3.5. on page 57)
2) Human Body Model (HBM): R=1.5 kΩ, C=100 pF
Stresses beyond those listed in the “Absolute Maxi-
mum Ratings” may cause permanent damage to the
device. This is a stress rating only. Functional opera-
tion of the device at these or any other conditions
beyond those indicated in the “Recommended Operat-
ing Conditions/Characteristics” of this specification is
not implied. Exposure to absolute maximum ratings
conditions for extended periods may affect device reli-
ability.
3.6.2. Recommended Operating Conditions
Symbol
TA
Parameter
Pin Name
Min.
0
Typ.
−
Max.
65
Unit
°C
Ambient Operating Temperature
Clock Frequency
fXTAL
XTAL1/2
−
20.25
5.0
−
MHz
V
VSUPA
Analog Supply Voltage
VSUPAF
VSUPAB
4.75
5.25
VSUPD
Digital Supply Voltage
VSUPD
3.15
3.3
3.45
V
Micronas