VDP 313xY  
ADVANCE INFORMATION  
Table 25: I2C control and status registers of the video backend  
(Registers are set to 0at reset, default values are recommendations)  
I2C Sub  
address  
Number  
of bits  
Mode Function  
Default Name  
(hex)  
(hex)  
Tube- and Picture-Measurements  
7B  
6B  
9
w v  
picture measurement start line  
PMST  
23  
bit[8:0]  
(TML+9)..511  
first line of picture measurement  
9
w v  
picture measurement stop line  
PMSO  
308  
bit[8:0]  
(PMST+1)..511  
last line of picture measurement  
7F  
25  
9
8
w v  
w/r  
tube measurement line  
bit[8:0] 0..511 start line for tube measurement  
TML  
15  
tube and picture measurement control  
0
PMC  
bit[0]  
bit[1]  
bit[2]  
0/1  
0/1  
0/1  
disable/enable tube measure-  
ment  
TMEN  
80/40 kHz bandwidth for  
picture measurement  
PMBW  
PMEN  
disable/enable picture  
measurement (writing a 1starts  
one measurement cycle)  
bit[3]  
0/1  
0/1  
large/small picture measurement  
window, will be disabled from  
bit[3] in address h32  
PMWIN  
OFSEN  
bit[4]  
measure / offset check for adc  
reserved  
bit[7:5]  
13  
16  
w/r  
white drive measurement control  
WDM  
bit[9:0]  
0..1023 RGB values for white drive beam 512  
current measurement  
WDRV  
bit[10]  
bit[11]  
reserved  
0/1  
RGB values for white drive beam  
current measurement disabled/  
enabled  
0
EWDM  
8
r
measurement result registers  
minimum in active picture  
18  
19  
1A  
1D  
1C  
1B  
MRMIN  
MRMAX  
MRWDR  
MRCR  
MRCG  
MRCB  
maximum in active picture  
white drive  
cutoff/leakage red  
cutoff/leakage green  
cutoff/leakage blue,  
read pulse starts tube measure-  
ment  
36  
Micronas  
 复制成功!