TPU 3035, TPU 3040
PRELIMINARY DATA SHEET
Command Codes, continued
Code
Function
Write Parameter
Read Parameter
Notes
Miscellaneous Data Commands
36
Read 8/30 Row
designation code
40 byte row data
only format 1 and 2 are supported
1st byte of row data is already hamming
decoded
15
53
Read VPS
Read WSS
framing code
counter
13 byte VPS data
= 51H
= incremented every VPS reception
= biphase decoded VPS bytes 3–15
framing code
counter
13 byte WSS data
= 78H
= incremented every WSS reception
= 102 WSS elements from group 1 on
54
55
Read CAPTION 1
Read CAPTION 2
counter
6 byte CAPTION data
= incremented every reception in field 1
= 3x oversampling
counter
6 byte CAPTION data
= incremented every reception in field 2
= 3x oversampling
19
31
16
Read Rolling Header
Read Rolling Time
Read Quality
24 byte rolling header
8 byte rolling time
every row 0 in cycle
using time pointer
updated every VBI
text lines
hamming errors
parity errors
soft errors
18
Read Reset Source
reset source
reset source:
bit0 = clock supervision
bit1 = voltage supervision
bit2 = watchdog
all bits in reset source are reset after read
46
47
Read Hamming
hamming (8,4) byte
data
hamming byte:
bit0–3= data
bit6 = hamming error
Read Hamming 2
hamming (24,18) 1st byte
hamming (24,18) 2nd byte
hamming (24,18) 3rd byte
address
mode
data
address:
bit0–5= address
bit7 = hamming error
mode:
bit0–4= mode
data:
bit0–6= data
33
Copy Data
source dram bank
source dram high
source dram low
length
copy data from DRAM to DRAM
destination dram bank
destination dram high
destination dram low
42
MICRONAS INTERMETALL