SDA9410
Preliminary Data Sheet
Output sync controller (OSCM/S)
Film mode IV: ADOPMOM=111
MOVMO
MOVPH
MOVTYP
VTSEQM
GMOTION
STOPMOMint
STOPMOSint
x
x
x
0
0
Frame repetition,
ABAB, 0011
STOPMOS
0
1
x
x
x
0
0
1
1
STOPMOM
STOPMOS
STOPMOS
0
VDU, film mode,
phase 0, PAL,
0001
1
x
1
x
x
x
0
1
1
x
VDU, film mode,
phase 1, PAL,
0010
STOPMOS
Simple 50, 0101
Linedoubling, AB,
010
Table 76
Adaptive operation modes
Example for explanation of the adaptive operation modes:
ADOPMOM = 4: Film mode I, RMODE=0
In this case the scan rate conversion algorithm is controlled by the signal MOVMO,
MOVTYP and MOVPH. If MOVMO is equal 0 the scan rate conversion mode is defined
by STOPMOM and STOPMOS (e.g. Micronas VDU). If MOVMO is equal 1 and MOVTYP
is equal 0 the scan rate conversion algorithm is changed depending on the MOVPH
signal to Micronas VDU, Film mode, PAL, phase 0 or 1. If MOVMO is equal 1 and
MOVTYP is equal 1 the scan rate conversion algorithm is changed depending on the
MOVPH signal to Micronas VDU, Film mode, NTSC, phase 0 or 1. In case of film mode
PAL, the MOVPH signal is constant for the applied material. In case of Film mode NTSC,
the MOVPH signal changes each 2th or 3th field, respectively.
I²C Bus
Sub address
Description
parameter
STOPMOM
STOPMOS
48h
4Ah
STatic OPeration MOdes Master
STatic OPeration MOdes Slave
ADaptive OPeration MOdes Master
ADOPMOM 49h
Table 77
Output write I²C Bus parameter
95
Micronas