SDA 9400  
Field detection and VIN delay  
CLK1  
H1  
H2  
VIN  
Vd  
(VINDEL * 128 + 1) * Tclk1  
x
Field 1(A)  
Ffd  
VIN  
(VINDEL * 128 + 1) * Tclk1  
Vd  
x
Ffd  
Field 2(B)  
Input write parameter  
Parameter  
Subaddress  
[Default value]  
Description  
VINDEL  
[0]  
01h  
Delay of the incoming V-Sync VIN (must be adjusted  
depending on the delay of the HIN signal)  
FIEINV  
00h  
Inversion of the internal field polarity  
1: Field A=1  
0: Field A=0  
[0]  
VCRMODE  
00h  
In case of non standard interlaced signals (VCR, Play-  
Stations) a filtering of the internal field signal has to be  
done (should also be used for normal TV signals)  
1: on  
0: off  
[1]  
In case of non-standard signals the field order is indeterminate (e.g. AAA... , BBB... , AAABAAAB...,  
etc.). Therefore a special filtering algorithm is implemented, which can be switched on by the  
parameter VCRMODE. It is recommended to set the parameter VCRMODE=1. In other case  
(VCRMODE=0) an additional internal signal VTSEQ is generated. This signal goes high  
(VTSEQ=1), if at least the last two fields were identical. Due to the fixed storage places of the fields  
in the internal memory block, this information is necessary for the scan rate conversion processing  
(see also Output sync controller (OSC) on page 40, it is recommended in case of VCRMODE=0 to  
choose an adaptive operation mode).  
The OPDEL parameter is used to adjust the outgoing V-Sync VOUT in relation to the incoming  
delayed V-Sync VIN. In case of 50 Hz to 100 Hz interlaced scan rate conversion the OPDEL  
parameter should be greater than half the number of lines of a field plus the internal processing  
delay (8 lines).  