PRELIMINARY DATA SHEET  
MSP 44x8G  
6.3.4. DCO-Registers  
6.4. Manual Mode:  
Description of Demodulator Read Registers  
Note: The use of this register is not recommended. It  
should be used only in cases where non-standard car-  
rier frequencies have to be processed. Please note,  
that the usage of user specific demodulation frequen-  
cies is not possible in combination with the Automatic  
Sound Select (MODUS[0]=1).  
Note: This register should be used only in cases  
where software compatibility to the MSP 44x0D is  
required. Using the STANDARD SELECTION register  
together with the STATUS register provides a more  
economic way to program the MSP 44x8G and to  
retrieve information from the MSP.  
When selecting a TV-sound standard by means of the  
STANDARD SELECT register, all frequency tuning is  
performed automatically.  
All registers except C_AD_BITs are 8 bits wide. They  
can be read out of the RAM of the MSP 44x8G.  
If manual setting of the tuning frequency is required, a  
set of 24-bit registers determining the mixing frequen-  
cies of the quadrature mixers can be written manually  
into the MSP. In Table 6–9, examples for DCO register  
programming are listed. It is necessary to separate  
these registers into two categories: low part and high  
part. The formula for the calculation of the INCR val-  
ues for any chosen IF frequency is as follows:  
All transmissions take place in 16-bit words. The valid  
8-bit data are the 8 LSBs of the received data word.  
If the Automatic Sound Select feature is not used, the  
NICAM or FM-identification parameters must be read  
and evaluated by the controller in order to enable  
appropriate switching of the channel select matrix of  
the baseband processing part. The FM-identification  
registers are described in Section 6.6.1. To handle the  
NICAM-sound and to observe the NICAM-quality, at  
least the registers C_AD_BITS and ERROR_RATE  
must be read and evaluated by the controller. Addi-  
tional data bits and CIB bits, if supplied by the NICAM  
transmitter, can be obtained by reading the registers  
ADD_BITS and CIB_BITS.  
INCRdec = int (f / fs 224)  
with: int = integer function  
f
= IF frequency in MHz  
fS = sampling frequency (18.432 MHz)  
Conversion of INCR into hex-format and separation of  
the 12-bit low and high parts lead to the required regis-  
ter values (DCO1_HI and _LO for MSP-Ch1, DCO2_HI  
and _LO for MSP-Ch2).  
Table 6–9: DCO registers for the MSP 44x8G; reset status: DCO_HI/LO = “00 00”  
DCO1_LO 00 93hex, DCO1_HI 00 9Bhex; DCO2_LO 00 A3hex, DCO2_HI 00 ABhex  
IF-Freq. [MHz]  
DCO_HI [hex]  
DCO_LO [hex]  
IF-Freq. [MHz]  
DCO_HI [hex]  
DCO_LO [hex]  
4.5  
03 E8  
00 00  
5.04  
5.5  
5.58  
5.7421875  
04 60  
04 C6  
04 D8  
04 FC  
00 00  
03 8E  
00 00  
00 AA  
5.76  
5.85  
5.94  
05 00  
05 14  
05 28  
00 00  
00 00  
00 00  
6.0  
6.2  
6.5  
6.552  
05 35  
05 61  
05 A4  
05 B0  
05 55  
0C 71  
07 1C  
00 00  
6.6  
6.65  
6.8  
05 BA  
05 C5  
05 E7  
0A AA  
0C 71  
01 C7  
7.02  
7.38  
06 18  
06 68  
00 00  
00 00  
7.2  
06 40  
06 90  
00 00  
00 00  
7.56  
Micronas  
77  