DATA SHEET
HAL880
5.3. Telegram Codes
Sync Bit
Data Bits (DAT)
The 14 Data Bits contain the register information.
Each telegram starts with the Sync Bit. This logical “0”
pulse defines the exact timing for tp0.
The registers use different number formats for the
Data Bits. These formats are explained in Section 5.4.
on page 30
Command Bits (COM)
In the Write command, the last bits are valid. If, for
example, the TC register (10 bits) is written, only the
last 10 bits are valid.
The Command code contains 3 bits and is a binary
number. Table 5–2 shows the available commands
and the corresponding codes for HAL880.
In the Read command, the first bits are valid. If, for
example, the TC register (10 bits) is read, only the first
10 bits are valid.
Command Parity Bit (CP)
This parity bit is “1”, if the number of zeros within the
3 Command Bits is uneven. The parity bit is “0”, if the
number of zeros is even.
Data Parity Bit (DP)
This parity bit is “1”, if the number of zeros within the
binary number is even. The parity bit is “0”, if the num-
ber of zeros is uneven.
Address Bits (ADR)
The Address code contains 4 bits and is a binary num-
ber. Table 5–3 on page 31 shows the available
addresses for the HAL880 registers.
Acknowledge
After each telegram, the output answers with the
Acknowledge signal. This logical “0” pulse defines the
exact timing for tpOUT
.
Address Parity Bit (AP)
This parity bit is “1”, if the number of zeros within the
4 Address bits is uneven. The parity bit is “0”, if the
number of zeros is even.
Table 5–2: Available commands
Command
READ
Code
Explanation
read a register
write a register
2
3
4
5
WRITE
PROM
program all nonvolatile registers (except the lock bits)
erase all nonvolatile registers (except the lock bits)
ERASE
Micronas
Feb. 23, 2009; DSH000152_001EN
29