DATA SHEET  
HAL880  
2.3. Calibration Procedure  
2.3.1. General Procedure  
Step 3: Define Calibration Points  
The calibration points 1 and 2 can be set inside the  
specified range. The corresponding values for VOUT1  
and VOUT2 result from the application requirements.  
For calibration in the system environment, the applica-  
tion kit from Micronas is recommended. It contains the  
hardware for the generation of the serial telegram for  
programming (Programmer Board Version 5.1) and the  
corresponding software (PC880) for the input of the  
register values.  
Lowclampingvoltage VOUT1,2 Highclampingvoltage  
For highest accuracy of the sensor, calibration points  
near the minimum and maximum input signal are  
recommended. The difference of the output voltage  
between calibration point 1 and calibration point 2  
should be more than 3.5 V.  
For the individual calibration of each sensor in the cus-  
tomer application, a two-point adjustment is recom-  
mended. The calibration has be done as follows:  
Step 1: Input of the registers which need not be  
adjusted individually  
Step 4: Calculation of VOQ and Sensitivity  
The magnetic circuit, the magnetic material with its  
temperature characteristics, the filter frequency, the  
output mode and the GP register value are given for  
this application. Therefore, the values of the following  
registers should be identical for all sensors of the  
customer application.  
Set the system to calibration point 1 and read the reg-  
ister D/A-READOUT. The result is the value  
D/A-READOUT1.  
Now, set the system to calibration point 2, read the  
register D/A-READOUT again, and get the value  
D/A-READOUT2.  
– FILTER  
(according to the maximum signal frequency)  
With these values, and the target values VOUT1 and  
– RANGE  
VOUT2, for the calibration points 1 and 2, respectively,  
(according to the maximum magnetic field at the  
sensor position)  
the values for Sensitivity and VOQ are calculated as:  
– OUTPUTMODE  
1
2
(Vout2 – Vout1)  
D/A-Readout2 – D/A-Readout1  
16384  
5
-- ---------------------------------------------------------------------------------- --------------  
Sensitivity =  
×
×
– TC, TCSQ, and TC-RANGE  
(depends on the material of the magnet and the  
other temperature dependencies of the application)  
– GP  
1
16  
Vout2 × 16384  
(if the customer wants to store own production infor-  
mation, it is not necessary to change this register)  
-----  
------------------------------------  
VOQ  
=
×
5
5
1024  
-----------  
[(D/A-Readout2 – 8192) × Sensitivity × 2] ×  
As the clamping voltages are given, they have an influ-  
ence on the D/A-readout value and therefore have to  
be set after the adjustment process.  
This calculation has to be done individually for each  
sensor.  
Write the appropriate settings into the HAL880  
registers.  
Next, write the calculated values for Sensitivity and  
VOQ into the IC for adjusting the sensor. At that time, it  
Step 2: Initialize DSP  
is also possible to store the application specific values  
for Clamp-Low and Clamp-High into the sensors  
EEPROM.  
As the D/A-READOUT register value depends on  
the  
settings  
of SENSITIVITY, VOQ, and  
CLAMP-LOW/HIGH, these registers have first to be  
initialized with defined values:  
– VOQINITIAL = 2.5 V  
– SensitivityINITIAL = 0.5  
– Clamp-Low = 0 V  
– Clamp-High = 4.999 V  
Micronas  
Feb. 23, 2009; DSH000152_001EN  
11