HAL880  
DATA SHEET  
Clamping Voltage  
D/A-Readout  
The output voltage range can be clamped in order to  
detect failures like short circuits to VDD or GND or an  
open circuit.  
The 14-bit D/A-READOUT register delivers the actual  
digital value of the applied magnetic field after the sig-  
nal processing. This register can be read out and is the  
basis for the calibration procedure of the sensor in the  
system environment.  
The CLAMP-LOW register contains the parameter for  
the lower limit. The lower clamping voltage is program-  
mable between 0 V and VDD/2. For VDD = 5 V, the  
register can be changed in steps of 9.77 mV.  
Note: The MSB and LSB are reversed compared with  
all the other registers. Please reverse this  
register after readout.  
The CLAMP-HIGH register contains the parameter for  
the upper limit. The upper clamping voltage is pro-  
grammable between 0 V and VDD. For VDD = 5 V, in  
steps of 9.77 mV.  
GP Register  
This register can be used to store some information,  
such as production date or customer serial number.  
Micronas will store production lot number, wafer num-  
ber, and x, y coordinates in three blocks of this regis-  
ters. The total register contains of four blocks with a  
length of 13 bit each. The customer can read out this  
information and store it in his own production data  
base for reference or he can change them and store  
own production information.  
Note: To enable programming of the GP register, bit 0  
of the MODE register has to be set to 1. This  
register is not a guarantee for traceability.  
LOCKR  
By setting the first bit of this 2-bit register, all registers  
will be locked and the sensor will no longer respond to  
any supply voltage modulation. This bit is active after  
the first power-off and power-on sequence after setting  
the LOCK bit.  
Warning: This register cannot be reset!  