HAL880
DATA SHEET
3.7. Open-Circuit Detection
at TJ = −40 °C to +140 °C. Typical Characteristics for TJ = 25 °C, after locking the sensor
Symbol
Parameter
Pin No.
Min.
Typ.
Max.
Unit
Comment
DD = 5 V
VOUT
Output Voltage at
Open VDD Line
3
0
0
0.15
V
V
RL = 10 kΩ to 200 kΩ
VOUT
Output Voltage at
Open GND Line
3
4.85
4.9
5.0
V
VDD = 5 V
10 kΩ ≥ RL ≤ 200 kΩ
RL: can be pull-up or pull-down resistor
3.8. Power-On Operation
at TJ = −40 °C to +140 °C, after programming and locking. Typical Characteristics for TJ = 25 °C.
Symbol
PORUP
Parameter
Min.
Typ.
3.4
Max.
Unit
V
−
−
−
−
Power-On Reset Voltage (UP)
Power-On Reset Voltage (DOWN)
PORDOWN
3.0
V
3.9. Overvoltage and Undervoltage Detection
at TJ = −40 °C to +140 °C. Typical Characteristics for TJ = 25 °C, after programming and locking
Symbol
Parameter
Pin No.
Min.
−
Typ.
4.2
Max.
4.3
Unit
V
Conditions
1)
V
Undervoltage Detection Level
Overvoltage Detection Level
1
1
DD,UV
DD,OV
1)
V
8.5
8.9
10.0
V
1)
If the supply voltage drops below V
or rises above V
, the output voltage is switched to V (≥97% of V at R = 10 kΩ to GND).
DD,OV DD DD L
DD,UV
The CLAMP-LOW register has to be set to a voltage ≥ 200 mV.
Note: The over- and undervoltage detection is activated only after locking the sensor!
3.10. Magnetic Characteristics
at TJ = −40 °C to +140 °C, VDD = 4.5 V to 5.5 V, GND = 0 V after programming and locking,
at Recommended Operation Conditions if not otherwise specified in the column “Conditions”.
Typical Characteristics for TJ = 25 °C and VDD = 5 V.
Symbol
Parameter
Pin No.
Min.
Typ.
Max.
Unit
Conditions
B = 0 mT, I
B
Magnetic Offset
3
−0.5
0
0.5
mT
= 0 mA, T = 25 °C,
OUT J
unadjusted sensor
Offset
ΔB
/ΔT
Magnetic Offset Change
−15
0
15
μT/K
B = 0 mT, I = 0 mA
Offset
OUT
due to T
J
22
Feb. 23, 2009; DSH000152_001EN
Micronas