ADVANCE INFORMATION  
HAL815  
5.5. Register Information  
ADC-READOUT  
– This register is read only.  
CLAMP-LOW  
– The register range is from 8192 up to 8191.  
– The register range is from 0 up to 1023.  
– The register value is calculated by:  
Low Clamping Voltage  
DEACTIVATE  
– This register can only be written.  
CLAMP-LOW =  
* 2048  
VDD  
– The register has to be written with 2063 decimal  
(80F hexadecimal) for the deactivation.  
– The sensor can be reset with an Activate pulse on  
the output pin or by switching off and on the supply  
voltage.  
CLAMP-HIGH  
– The register range is from 0 up to 2047.  
– The register value is calculated by:  
High Clamping Voltage  
5.6. Programming Information  
CLAMP-HIGH =  
* 2048  
VDD  
If the content of any register (except the lock registers)  
is to be changed, the desired value must first be writ-  
ten into the corresponding RAM register. Before read-  
ing out the RAM register again, the register value must  
be permanently stored in the EEPROM.  
VOQ  
– The register range is from 1024 up to 1023.  
– The register value is calculated by:  
VOQ  
Permanently storing a value in the EEPROM is done  
by first sending an ERASE command followed by  
sending a PROM command. The address within the  
ERASE and PROM commands is not important.  
ERASE and PROM act on all registers in parallel.  
VOQ =  
* 1024  
VDD  
If all HAL 815 registers are to be changed, all writing  
commands can be sent one after the other, followed by  
sending one ERASE and PROM command at the end.  
SENSITIVITY  
– The register range is from 8192 up to 8191.  
– The register value is calculated by:  
Sensitivity  
SENSITIVITY =  
2048  
TC and TCSQ  
– The TC register range is from 31 up to 31.  
– The TCSQ register range is from 0 up to 31.  
Please refer Section 4.2. on page 17 for the recom-  
mended values.  
MODE  
– The register range is from 0 up to 63 and contains  
the settings for FILTER and RANGE:  
MODE = FILTER * 8 + RANGE  
Please refer Section 2.2. on page 7 for the available  
FILTER and RANGE values.  