PRELIMINARY DATA SHEET  
HAL805  
Clamping Voltage  
2.3. Calibration Procedure  
2.3.1. General Procedure  
The output voltage range can be clamped in order to  
detect failures like shorts to VDD or GND or an open  
circuit.  
For calibration in the system environment, the applica-  
tion kit from Micronas is recommended. It contains the  
hardware for the generation of the serial telegram for  
programming and the corresponding software for the  
input of the register values.  
The CLAMP-LOW register contains the parameter for  
the lower limit. The lower clamping voltage is program-  
mable between 0 V and VDD/2. For VDD = 5 V, the reg-  
ister can be changed in steps of 2.44 mV.  
In this section, programming of the sensor using this  
programming tool is explained. Please refer to  
Section 5. on page 19 for information about program-  
ming without this tool.  
The CLAMP-HIGH register contains the parameter for  
the upper limit. The upper clamping voltage is pro-  
grammable between 0 V and VDD. For VDD = 5 V, in  
steps of 2.44 mV.  
For the individual calibration of each sensor in the cus-  
tomer application, a two point adjustment is recom-  
mended (see Fig. 27 for an example). When using  
the application kit, the calibration can be done in three  
steps:  
LOCKR  
By setting this 1-bit register, all registers will be locked,  
and the sensor will no longer respond to any supply  
voltage modulation.  
Step 1: Input of the registers which need not be  
adjusted individually  
Warning: This register cannot be reset!  
ADC-READOUT  
The magnetic circuit, the magnetic material with its  
temperature characteristics, the filter frequency, and  
low and high clamping voltage are given for this appli-  
cation.  
This 14-bit register delivers the actual digital value of  
the applied magnetic field before the signal process-  
ing. This register can be read out and is the basis for  
the calibration procedure of the sensor in the system  
environment.  
Therefore, the values of the following registers should  
be identical for all sensors of the customer application.  
FILTER  
(according to the maximum signal frequency)  
RANGE  
(according to the maximum magnetic field at the  
sensor position)  
TC and TCSQ  
(depends on the material of the magnet and the  
other temperature dependencies of the application)  
CLAMP-LOW and CLAMP-HIGH  
(according to the application requirements)  
Write the appropriate settings into the HAL 805 regis-  
ters.  
Micronas  
9