HAL57x, HAL58x
DATA SHEET
3.5. Recommended Operating Conditions
Functional operation of the device beyond those indicated in the “Recommended Operating Conditions/Characteris-
tics” is not implied and may result in unpredictable behavior, reduce reliability and lifetime of the device.
All voltages listed are referenced to ground (GND).
Symbol
VDD
Parameter
Pin No.
Min.
3.75
−40
Typ.
Max.
24
Unit
V
Supply Voltage
1
TA
Ambient Temperature for
Continuous Operation
851)
°C
ton
Supply Time for Pulsed Mode
−
30
−
μs
1)
when using the”K” type and VDD ≤16 V
Note: Due to the high power dissipation at high current consumption, there is a difference between the ambient tem-
perature (TA) and junction temperature. The power dissipation can be reduced by repeatedly switching the
supply voltage on and off (pulse mode). Please refer to Section 5.4. on page 34 for details.
14
Dec. 22, 2008; DSH000145_003EN
Micronas