HAL55x, HAL56x
DATA SHEET
4.2. HAL560
Applications
The HAL560 is a low-sensitive unipolar switching sen-
sor with an inverted output (see Fig. 4–5).
The HAL560 is designed for applications with one
magnetic polarity and strong magnetic amplitudes at
the sensor position where an inverted output signal is
required such as:
The sensor turns to low current consumption with the
magnetic south pole on the branded side of the pack-
age and turns to high current consumption if the mag-
netic field is removed. It does not respond to the mag-
netic north pole on the branded side.
– applications with strong magnets,
– solid state switches,
– contactless solutions to replace micro switches,
– position and end point detection, and
– rotating speed measurement.
For correct functioning in the application, the sensor
requires only the magnetic south pole on the branded
side of the package.
Magnetic Features:
Current consumption
– switching type: unipolar inverted
– low sensitivity
IDDhigh
BHYS
– typical BON: 45.6 mT at room temperature
– typical BOFF: 51.7 mT at room temperature
IDDlow
– operates with static magnetic fields and dynamic
magnetic fields up to 10 kHz
0
BON
BOFF
B
Fig. 4–5: Definition of magnetic switching points for
the HAL560
Magnetic Characteristics at TJ = −40 °C to +140 °C, VDD = 4 V to 24 V,
Typical Characteristics for VDD = 12 V
Magnetic flux density values of switching points.
Positive flux density values refer to the magnetic south pole at the branded side of the package.
Parameter
On point B
Typ.
Off point B
Typ.
Hysteresis B
HYS
Magnetic Offset
Unit
ON
OFF
T
Min.
41
Max.
52
Min.
47
Max.
Min.
Typ.
6.5
6
Max.
Min.
Typ.
49.8
49.5
48.4
47.3
Max.
J
−40 °C
25 °C
46.5
53
59
4
3
2
2
10
9
mT
mT
mT
mT
41
46.5
52
46
52.5
58.5
57.5
56.5
100 °C
140 °C
41
45.7
52
45
51.1
5.4
5
8
39
44.8
51
43.5
49.8
8
The hysteresis is the difference between the switching points BHYS = BON − BOFF
The magnetic offset is the mean value of the switching points BOFFSET = (BON + BOFF) / 2
20
Aug. 11, 2009; DSH000026_004EN
Micronas