DATA SHEET
HAL401
3.5. Recommended Operating Conditions
Functional operation of the device beyond those indicated in the “Recommended Operating Conditions” of this specifi-
cation is not implied, may result in unpredictable behavior of the device and may reduce reliability and lifetime.
All voltages listed are referenced to ground (GND).
Symbol
Parameter
Pin No.
2, 3
2, 3
2, 3
1
Min.
–2.25
–1
Max.
2.25
1
Unit
mA
mA
nF
Remarks
T = 25 °C
I
O
I
O
Continuous Output Current
Continuous Output Current
Load Capacitance
J
T = 170 °C
J
C
–
1
L
V
DD
Supply Voltage
4.8
12
V
see Fig. 3–2
B
Magnetic Field Range
–50
50
mT
V
DD
power dissipation limit
12 V
11.5 V
8.0 V
6.8 V
4.8 V
4.5 V
min. V
DD
for specified
sensitivity
–40 °C
150 °C T
A
25 °C
125 °C
Fig. 3–2: Recommended Operating Supply Voltage
Micronas
9