DATA SHEET  
HAL320  
3.7. Magnetic Characteristics at T = –40 °C to +170 °C, V = 4.5 V to 24 V  
J
DD  
Typical Characteristics for V = 12 V  
DD  
Magnetic flux density values of switching points (Condition: –10 mT < B < 10 mT)  
0
Positive flux density values refer to the magnetic south pole at the branded side ot the package. ΔB = B – B  
S1  
S2  
Unit  
Parameter  
–40 °C  
25 °C  
170 °C  
Min.  
–1.5  
Typ.  
Max.  
2.5  
Min.  
-1.5  
Typ.  
Max.  
Min.  
–2.5  
Typ.  
Max.  
On point ΔB  
1.2  
–0.6  
1.8  
1.2  
–0.6  
1.8  
2.5  
1.1  
–0.4  
1.5  
3.5  
mT  
mT  
mT  
mT  
ON  
ΔB > ΔB  
ON  
Off point ΔB  
–2.5  
1
1.5  
4
–2.5  
1
1.5  
4
–3.5  
0.8  
–3  
2.5  
4
OFF  
ΔB < ΔB  
OFF  
Hysteresis  
ΔB = ΔB – ΔB  
OFF  
HYS  
ON  
Offset ΔB  
= B + ΔB )/2  
OFF  
–2  
0.3  
2
–2  
0.3  
2
0.4  
3
OFFSET  
ON  
In back-biased applications, sensitivity mismatch between the two Hall plates S and S can lead to an additional offset  
1
2
of the magnetic switching points. In back-biased applications with the magnetic preinduction B , this sensitivity mis-  
0
match generates the magnetic offset ΔB  
= |S – S |/S @ B + ΔB  
.
OFFSETbb  
1
2
1
0
OFFSET  
Parameter  
–40 °C  
25 °C  
170 °C  
Unit  
1)  
2)  
2)  
2)  
Sensitivity mismatch  
|S – S |/S  
1
1.5  
1.0  
0.5  
%
1
2
1)  
2)  
Mechanical stress from packaging can influence sensitivity mismatch.  
All values are typical values.  
The magnetic switching points are checked at room temperature at a magnetic preinduction of B = 150 mT.  
0
These magnetic parameters may change under external pressure and during the lifetime of the sensor.  
Parameter  
25 °C  
Unit  
Min.  
–4.5  
–5.5  
1
Typ.  
Max.  
5.5  
4.5  
4
On point ΔB  
Off point ΔB  
1.5  
–0.3  
1.8  
mT  
mT  
mT  
mT  
ONbb  
OFFbb  
Hysteresis ΔB  
HYS  
Offset ΔB  
–5  
0.6  
+5  
OFFSETbb  
Output Voltage  
V
OH  
V
OL  
DB  
DB  
0
DB  
DB  
ON max  
OFF min  
OFF  
ON  
DB  
HYS  
ΔB = B – B  
S1  
S2  
Fig. 3–7: Definition of switching points and hysteresis  