2.4. Example: Calibration of a Position Switch  
The following description explains the calibration pro-  
cedure using a position switch as an example.  
– The mechanical switching points are given.  
– temperature coefficient of the magnet: 500 ppm/K  
Step 1: Input of the registers which need not be  
adjusted individually  
The register values for the following registers are given  
for all sensors in the application:  
– FILTER  
Select the filter frequency: 500 Hz  
– RANGE  
Select the magnetic field range: 30 mT  
– TC  
For this magnetic material: 6  
– TCSQ  
For this magnetic material: 14  
Enter these values in the software, and use the “write  
and store” command to store these values perma-  
nently in the registers.  
Step 2: Calculation of the Sensor Parameters  
Set the system to the calibration point where the sen-  
sor output must be high, and press “Readout B  
”.  
OFF  
Set the system to the calibration point where the sen-  
sor output must be low, and press “Readout B  
ON  
Now, adjust the hysteresis to 80%, and press the key  
“calibrate and store”.  
Step 3: Locking the Sensor  
The last step is activating the LOCK function with the  
“LOCK” command. The sensor is now locked and does  
not respond to any programming or reading com-  
mands. Please note that the LOCK function becomes  
effective after power-down and power-up of the Hall-  
IC.  
Warning: The LOCKR register cannot be reset!  