CCU 3000, CCU 3000-I
CCU 3001, CCU 3001-I
022AH
Timer 1 Adder Low Byte
Bit
7
Reset
Read
Write
x
x
x
x
x
x
x
x
adder bit 7
adder bit 6
adder bit 5
adder bit 4
adder bit 3
adder bit 2
adder bit 1
adder bit 0 (LSB)
adder bit 7
adder bit 6
adder bit 5
adder bit 4
adder bit 3
adder bit 2
adder bit 1
adder bit 0 (LSB)
6
5
4
3
2
1
0
022BH
Timer 1 Adder High Byte
Bit
7
Reset
Read
Write
x
x
x
x
x
x
x
x
adder bit 15 (MSB)
adder bit 14
adder bit 13
adder bit 12
adder bit 11
adder bit 10
adder bit 9
adder bit 8
adder bit 15 (MSB)
adder bit 14
adder bit 13
adder bit 12
adder bit 11
adder bit 10
adder bit 9
adder bit 8
6
5
4
3
2
1
0
022CH
Timer 2 Control Register 1
Bit
7
Reset
Read
Write
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
‘1’ = second serial input level enabled
clock select, bit 1: ‘00’ = pin, ‘01’ = fosc.,
clock select, bit 0: ‘10’ = PHI2, ‘11’ = no clock
counter stop: ‘0’ = disabled , ‘1’ = carry out accu
start condition, bit 1: ‘00’= none (always active),
start condition, bit 0: ‘01’ = edge, ‘10’ = pin, ‘11’ =\pin
‘1’ = half load enabled
6
5
4
3
2
1
0
active edge selection: ‘0’ = rising ‘1’ = falling
48
MICRONAS INTERMETALL