 浏览型号M29DW256G7ANF6F的Datasheet PDF文件第29页浏览型号M29DW256G7ANF6F的Datasheet PDF文件第30页浏览型号M29DW256G7ANF6F的Datasheet PDF文件第31页浏览型号M29DW256G7ANF6F的Datasheet PDF文件第32页浏览型号M29DW256G7ANF6F的Datasheet PDF文件第34页浏览型号M29DW256G7ANF6F的Datasheet PDF文件第35页浏览型号M29DW256G7ANF6F的Datasheet PDF文件第36页浏览型号M29DW256G7ANF6F的Datasheet PDF文件第37页  
256Mb: 3V Embedded Parallel NOR Flash  
Program Operations  
Program Operations  
PROGRAM Command  
The PROGRAM (A0h) command can be used to program a value to one address in the  
memory array. The command requires four bus WRITE operations, and the final WRITE  
operation latches the address and data in the internal state machine and starts the pro-  
gram/erase controller.  
Programming can be suspended and then resumed by issuing a PROGRAM SUSPEND  
command and a PROGRAM RESUME command, respectively.  
If the address falls in a protected block, the PROGRAM command is ignored, and the  
data remains unchanged. The status register is not read, and no error condition is given.  
After programming has started, bus READ operations output the status register content.  
A bus READ operation from a bank different from the one whose blocks are being pro-  
grammed will output the memory array content.  
After the PROGRAM operation has completed, the device returns to read mode, unless  
an error has occurred. When an error occurs, bus READ operations to the device contin-  
ue to output the status register. A READ/RESET command must be issued to reset the  
error condition and return the device to read mode.  
The PROGRAM command cannot change a bit set to 0 back to 1, and an attempt to do  
so is masked during a PROGRAM operation. Instead, an ERASE command must be used  
to set all bits in one memory block or in the entire memory from 0 to 1.  
The PROGRAM operation is aborted by performing a reset or by powering-down the de-  
vice. In this case, data integrity cannot be ensured, and it is recommended that the  
aborted data be reprogrammed.  
UNLOCK BYPASS PROGRAM Command  
When the device is in unlock bypass mode, the UNLOCK BYPASS PROGRAM (A0h)  
command can be used to program one address in the memory array. The command re-  
quires two bus WRITE operations instead of four required by a standard PROGRAM  
command; the final WRITE operation latches the address and data and starts the pro-  
gram/erase controller (The standard PROGRAM command requires four bus WRITE op-  
erations). This UNLOCK BYPASS PROGRAM operation behaves identically to the PRO-  
GRAM operation. The operation cannot be aborted. A bus READ operation from the  
memory outputs the status register. A bus READ operation from a bank different from  
the one whose blocks are being programmed will output the memory array content.  
WRITE TO BUFFER PROGRAM Command  
The WRITE TO BUFFER PROGRAM (25h) command makes use of the 32-word program  
buffer to speed up programming. A maximum of 32 words can be loaded into the pro-  
gram buffer; each write buffer has the same A[23:5]. The WRITE TO BUFFER PROGRAM  
command dramatically reduces system programming time compared to the standard  
non-buffered PROGRAM command.  
When issuing a WRITE TO BUFFER PROGRAM command, V PP/WP# can be either held  
HIGH or raised to VPPH. Also, it can be held LOW if the block is not one of the four outer-  
PDF: 09005aef84ecabef  