 浏览型号JS28F640J3F75A的Datasheet PDF文件第46页浏览型号JS28F640J3F75A的Datasheet PDF文件第47页浏览型号JS28F640J3F75A的Datasheet PDF文件第48页浏览型号JS28F640J3F75A的Datasheet PDF文件第49页浏览型号JS28F640J3F75A的Datasheet PDF文件第51页浏览型号JS28F640J3F75A的Datasheet PDF文件第52页浏览型号JS28F640J3F75A的Datasheet PDF文件第53页浏览型号JS28F640J3F75A的Datasheet PDF文件第54页  
Numonyx® Embedded Flash Memory (J3 65 nm) Single Bit per Cell (SBC)  
Figure 18: Byte/Word Program Flowchart  
Start  
Bus  
Operation  
Command  
Comments  
Setup Byte/  
Data = 40H  
Write 40H,  
Address  
Write  
Write  
Word Program Addr = Location to Be Programmed  
Byte/Word  
Program  
Data = Data to Be Programmed  
Addr = Location to Be Programmed  
Write Data and  
Address  
Read  
(Note 1)  
Status Register Data  
Check SR.7  
1 = WSM Ready  
0 = WSM Busy  
Read Status  
Register  
Standby  
1. Toggling OE# (low to high to low) updates the status register. This  
can be done in place of issuing the Read Status Register command.  
Repeat for subsequent programming operations.  
0
SR.7 =  
1
SR full status check can be done after each program operation, or  
after a sequence of programming operations.  
Full Status  
Write FFH after the last program operation to place device in read  
array mode.  
Check if Desired  
Byte/Word  
Program Complete  
FULL STATUS CHECK PROCEDURE  
Bus  
Operation  
Command  
Comments  
Check SR.3  
1 = Programming to Voltage Error  
Detect  
Read Status  
Register Data  
(See Above)  
Standby  
1
Check SR.1  
SR.3 =  
SR.1 =  
SR.4 =  
Voltage Range Error  
1 = Device Protect Detect  
RP# = VIH, Block Lock-Bit Is Set  
Only required for systems  
implemeting lock-bit configuration.  
Standby  
Standby  
0
0
0
1
1
Check SR.4  
1 = Programming Error  
Device Protect Error  
Programming Error  
Toggling OE# (low to high to low) updates the status register. This can  
be done in place of issuing the Read Status Register command.  
Repeat for subsequent programming operations.  
SR.4, SR.3 and SR.1 are only cleared by the Clear Status Register  
command in cases where multiple locations are programmed before  
full status is checked.  
Byte/Word  
Program  
Successful  
If an error is detected, clear the status register before attempting retry  