 浏览型号PIC18F4520-I/ML的Datasheet PDF文件第32页浏览型号PIC18F4520-I/ML的Datasheet PDF文件第33页浏览型号PIC18F4520-I/ML的Datasheet PDF文件第34页浏览型号PIC18F4520-I/ML的Datasheet PDF文件第35页浏览型号PIC18F4520-I/ML的Datasheet PDF文件第37页浏览型号PIC18F4520-I/ML的Datasheet PDF文件第38页浏览型号PIC18F4520-I/ML的Datasheet PDF文件第39页浏览型号PIC18F4520-I/ML的Datasheet PDF文件第40页  
PIC18F2420/2520/4420/4520  
3.1.3  
CLOCK TRANSITIONS AND STATUS  
INDICATORS  
3.2  
Run Modes  
In the Run modes, clocks to both the core and  
peripherals are active. The difference between these  
modes is the clock source.  
The length of the transition between clock sources is  
the sum of two cycles of the old clock source and three  
to four cycles of the new clock source. This formula  
assumes that the new clock source is stable.  
3.2.1  
PRI_RUN MODE  
Three bits indicate the current clock source and its  
status. They are:  
The PRI_RUN mode is the normal, full-power execu-  
tion mode of the microcontroller. This is also the default  
mode upon a device Reset unless Two-Speed Start-up  
is enabled (see Section 23.3 “Two-Speed Start-up”  
for details). In this mode, the OSTS bit is set. The IOFS  
bit may be set if the internal oscillator block is the  
primary clock source (see Section 2.7.1 “Oscillator  
Control Register”).  
• OSTS (OSCCON<3>)  
• IOFS (OSCCON<2>)  
• T1RUN (T1CON<6>)  
In general, only one of these bits will be set while in a  
given power-managed mode. When the OSTS bit is  
set, the primary clock is providing the device clock.  
When the IOFS bit is set, the INTOSC output is  
providing a stable 8 MHz clock source to a divider that  
actually drives the device clock. When the T1RUN bit is  
set, the Timer1 oscillator is providing the clock. If none  
of these bits are set, then either the INTRC clock  
source is clocking the device or the INTOSC source is  
not yet stable.  
3.2.2  
SEC_RUN MODE  
The SEC_RUN mode is the compatible mode to the  
“clock switching” feature offered in other PIC18  
devices. In this mode, the CPU and peripherals are  
clocked from the Timer1 oscillator. This gives users the  
option of lower power consumption while still using a  
high-accuracy clock source.  
If the internal oscillator block is configured as the  
primary clock source by the FOSC<3:0> Configuration  
bits, then both the OSTS and IOFS bits may be set  
when in PRI_RUN or PRI_IDLE modes. This indicates  
that the primary clock (INTOSC output) is generating a  
stable 8 MHz output. Entering another power-managed  
RC mode at the same frequency would clear the OSTS  
bit.  
SEC_RUN mode is entered by setting the SCS<1:0>  
bits to ‘01’. The device clock source is switched to the  
Timer1 oscillator (see Figure 3-1), the primary oscilla-  
tor is shut down, the T1RUN bit (T1CON<6>) is set and  
the OSTS bit is cleared.  
Note:  
The Timer1 oscillator should already be  
running prior to entering SEC_RUN mode.  
If the T1OSCEN bit is not set when the  
SCS<1:0> bits are set to ‘01’, entry to  
SEC_RUN mode will not occur. If the  
Timer1 oscillator is enabled, but not yet  
running, device clocks will be delayed until  
the oscillator has started. In such situa-  
tions, initial oscillator operation is far from  
stable and unpredictable operation may  
result.  
Note 1: Caution should be used when modifying a  
single IRCF bit. If VDD is less than 3V, it is  
possible to select a higher clock speed  
than is supported by the low VDD.  
Improper device operation may result if  
the VDD/FOSC specifications are violated.  
2: Executing a SLEEP instruction does not  
necessarily place the device into Sleep  
mode. It acts as the trigger to place the  
controller into either the Sleep mode or  
one of the Idle modes, depending on the  
setting of the IDLEN bit.  
On transitions from SEC_RUN mode to PRI_RUN  
mode, the peripherals and CPU continue to be clocked  
from the Timer1 oscillator while the primary clock is  
started. When the primary clock becomes ready, a  
clock switch back to the primary clock occurs (see  
Figure 3-2). When the clock switch is complete, the  
T1RUN bit is cleared, the OSTS bit is set and the  
primary clock is providing the clock. The IDLEN and  
SCS bits are not affected by the wake-up; the Timer1  
oscillator continues to run.  
3.1.4  
MULTIPLE SLEEP COMMANDS  
The power-managed mode that is invoked with the  
SLEEP instruction is determined by the setting of the  
IDLEN bit at the time the instruction is executed. If  
another SLEEPinstruction is executed, the device will  
enter the power-managed mode specified by IDLEN at  
that time. If IDLEN has changed, the device will enter  
the new power-managed mode specified by the new  
setting.  
DS39631E-page 34  
Advance Information  
© 2008 Microchip Technology Inc.  
 复制成功!