15.3.3
SOFTWARE INTERRUPT
15.3 Capture Mode
When the Capture mode is changed, a false capture
interrupt may be generated. The user should keep bit
CCP1IE (PIE1<2>) clear to avoid false interrupts and
should clear the flag bit, CCP1IF, following any such
change in operating mode.
In Capture mode, CCPR1H:CCPR1L captures the 16-bit
value of the TMR1 or TMR3 registers when an event
occurs on pin RC2/CCP1/P1A. An event is defined as
one of the following:
• every falling edge
• every rising edge
15.3.4
CCP PRESCALER
• every 4th rising edge
• every 16th rising edge
There are four prescaler settings specified by bits
CCP1M3:CCP1M0. Whenever the CCP module is
turned off, or the CCP module is not in Capture mode,
the prescaler counter is cleared. This means that any
Reset will clear the prescaler counter.
The event is selected by control bits, CCP1M3:CCP1M0
(CCP1CON<3:0>). When a capture is made, the inter-
rupt request flag bit, CCP1IF (PIR1<2>), is set; it must
be cleared in software. If another capture occurs before
the value in register CCPR1 is read, the old captured
value is overwritten by the new captured value.
Switching from one capture prescaler to another may
generate an interrupt. Also, the prescaler counter will
not be cleared, therefore, the first capture may be from
a non-zero prescaler. Example 15-1 shows the recom-
mended method for switching between capture
prescalers. This example also clears the prescaler
counter and will not generate the “false” interrupt.
15.3.1
CCP PIN CONFIGURATION
In Capture mode, the RC2/CCP1/P1A pin should be
configured as an input by setting the TRISC<2> bit.
Note:
If the RC2/CCP1/P1A is configured as an
output, a write to the port can cause a
capture condition.
EXAMPLE 15-1:
CHANGING BETWEEN
CAPTURE PRESCALERS
CLRF
CCP1CON, F
; Turn CCP module off
; Load WREG with the
; new prescaler mode
; value and CCP ON
; Load CCP1CON with
; this value
MOVLW
NEW_CAPT_PS
CCP1CON
15.3.2
TIMER1/TIMER3 MODE SELECTION
The timers that are to be used with the capture feature
(either Timer1 and/or Timer3) must be running in Timer
mode or Synchronized Counter mode. In Asynchro-
nous Counter mode, the capture operation may not
work. The timer to be used with each CCP module is
selected in the T3CON register.
MOVWF
FIGURE 15-1:
CAPTURE MODE OPERATION BLOCK DIAGRAM
TMR3H
TMR3L
CCPR1L
TMR1L
Set Flag bit CCP1IF
T3CCP2
TMR3
Enable
Prescaler
÷ 1, 4, 16
CCP1 pin
CCPR1H
TMR1
and
Edge Detect
T3CCP2
Enable
TMR1H
CCP1CON<3:0>
Q’s
Set Flag bit CCP2IF
T3CCP1
TMR3H
TMR3L
CCPR2L
TMR1L
T3CCP2
TMR3
Enable
Prescaler
÷ 1, 4, 16
CCP2 pin
CCPR2H
TMR1
and
Edge Detect
Enable
T3CCP2
T3CCP1
TMR1H
CCP2CON<3:0>
Q’s
2003 Microchip Technology Inc.