型号: PIC16F777-I/PT
PDF下载: 下载PDF文件 查看货源
内容描述: 28 /40/ 44引脚, 8位CMOS闪存微控制器与10位A / D和纳瓦技术 [28/40/44-Pin, 8-Bit CMOS Flash Microcontrollers with 10-Bit A/D and nanoWatt Technology]
分类和应用: 闪存微控制器
文件页数/大小: 276 页 / 4898 K
品牌: MICROCHIP [ MICROCHIP ]
 浏览型号PIC16F777-I/PT的Datasheet PDF文件第128页浏览型号PIC16F777-I/PT的Datasheet PDF文件第129页浏览型号PIC16F777-I/PT的Datasheet PDF文件第130页浏览型号PIC16F777-I/PT的Datasheet PDF文件第131页浏览型号PIC16F777-I/PT的Datasheet PDF文件第133页浏览型号PIC16F777-I/PT的Datasheet PDF文件第134页浏览型号PIC16F777-I/PT的Datasheet PDF文件第135页浏览型号PIC16F777-I/PT的Datasheet PDF文件第136页  
PIC16F7X7  
If SDA is low, a bus collision has occurred (i.e., another  
master is attempting to transmit a data ‘0’, see  
Figure 10-29). If SDA is sampled high, the BRG is  
reloaded and begins counting. If SDA goes from high-  
to-low before the BRG times out, no bus collision  
occurs because no two masters can assert SDA at  
exactly the same time.  
10.4.17.2 Bus Collision During a Repeated  
Start Condition  
During a Repeated Start condition, a bus collision  
occurs if:  
a) A low level is sampled on SDA when SCL goes  
from low level to high level.  
b) SCL goes low before SDA is asserted low,  
indicating that another master is attempting to  
transmit a data ‘1’.  
If SCL goes from high-to-low before the BRG times out  
and SDA has not already been asserted, a bus collision  
occurs. In this case, another master is attempting to  
transmit a data ‘1’ during the Repeated Start condition  
(Figure 10-30).  
When the user deasserts SDA and the pin is allowed to  
float high, the BRG is loaded with SSPADD<6:0> and  
counts down to 0. The SCL pin is then deasserted and  
when sampled high, the SDA pin is sampled.  
If at the end of the BRG time-out, both SCL and SDA are  
still high, the SDA pin is driven low and the BRG is  
reloaded and begins counting. At the end of the count,  
regardless of the status of the SCL pin, the SCL pin is  
driven low and the Repeated Start condition is complete.  
FIGURE 10-29:  
BUS COLLISION DURING A REPEATED START CONDITION (CASE 1)  
SDA  
SCL  
Sample SDA when SCL goes high.  
If SDA = 0, set BCLIF and release SDA and SCL.  
RSEN  
BCLIF  
Cleared in software  
0’  
S
0’  
SSPIF  
FIGURE 10-30:  
BUS COLLISION DURING A REPEATED START CONDITION (CASE 2)  
TBRG  
TBRG  
SDA  
SCL  
SCL goes low before SDA,  
set BCLIF. Release SDA and SCL.  
BCLIF  
RSEN  
Interrupt cleared  
in software  
0’  
S
SSPIF  
DS30498C-page 130  
2004 Microchip Technology Inc.  