HCS301
TABLE 6-1:
PROGRAMMING/VERIFY TIMING REQUIREMENTS
VDD = 5.0V ± 10%, 25 °C ± 5 °C
Parameter
Symbol
TPS
Min.
3.5
3.5
50
Max.
4.5
—
Units
ms
ms
µs
Program mode setup time
Hold time 1
TPH1
TPH2
TPBW
TPROG
TWC
Hold time 2
—
Bulk Write time
4.0
4.0
50
—
ms
ms
ms
µs
Program delay time
Program cycle time
Clock low time
—
—
TCLKL
TCLKH
TDS
50
—
Clock high time
50
—
µs
µs(1)
µs(1)
µs(1)
Data setup time
0
—
Data hold time
TDH
TDV
30
—
—
Data out valid time
30
Note 1: Typical values - not tested in production.
DS21143B-page 14