PRELIMINARY  
ML4435  
FUNCTIONAL DESCRIPTION  
mutation to achieve rotational motion. Electronic com-  
mutation requires the switching on and off of the power  
switches of a 3 phase half bridge. For torque production  
to be achieved in one direction the commutation is dic-  
tated by the rotor’s position. Electronic commutation in  
the ML4435 is achieved by turning on and off, in the  
proper sequence, one L output from one phase and one H  
output from another phase. There are six combinations of  
L and H outputs (six switching states) that constitute a full  
commutation cycle as illustrated in Table 1 labeled state  
A through F. This switching sequence is programmed into  
the commutation state machine as illustrated in Figure 6.  
Clocking of the commutation state machine is provided by  
the output of a VCO.  
(pin 2) proportional to the input voltage to the voltage  
controlled oscillator SPEED FB (pin 18). The proportion of  
frequency to voltage or VCO constant Kv is set by a resistor  
to ground on RVCO (pin 4) and capacitor to ground on  
CVCO (pin 20) as shown in Figure 7. RVCO sets up a  
current proportional to the VCO input voltage SPEED FB  
minus 0.7V. This current is used to charge and discharge  
CVCO between the threshold voltages of 2V and 3.75V as  
shown in Figure 7. RVCO has a lower voltage limit of 0.2V.  
The resulting triangle wave of CVCO corresponds to the  
clock on the TACH pin, this is also illustrated in Figure 7. Kv  
should be set so that the VCO output frequency corresponds  
to the maximum commutation frequency FMAX and thus the  
maximum motor speed when the VCO input is equal to or  
slightly less than 6V. CVCO and RVCO can be selected by  
rst calculating FMAX and then using the selection graph in  
Figure 8. FMAX is calculated as follows:  
VOLTAGE CONTROLLED OSCILLATOR  
The VCO outputs a TTL compatible clock on the TACH  
FMAX = 0.05 x RPMMAX x N  
OUTPUT DRIVERS  
Where: RPMMAX = The maximum speed of operation  
(RPM). N = The number of magnetic poles (Unitless).  
LA  
LB  
LC  
HA  
HB  
HC  
TACH  
A
B
C
LOW LOW HI  
H
LOW HI H HI  
H
H
H
The TACH (pin 2) outputs the VCO frequency. This is 6  
LOW LOW HI H HI  
H
H
LOW HI  
LOW HI  
HI  
HI  
H
H
LOW LOW HI  
D
E
LOW LOW HI H HI  
H
H
LOW  
LOW  
LOW HI  
LOW HI  
H
H
LOW HI H HI  
SPEED FB  
F
LOW LOW HI H HI  
H
-
LEVEL  
SHIFT  
0. V  
+
= DRIVER ON  
CVCO  
3. 5V  
Table 1. Communication Control States  
20  
2V  
VOLTA E  
CONTROLLED  
OSCILLATOR  
RVCO  
4
COMMUTATION  
STATE MACHINE  
R
0.9V  
CLK VCO  
3 s  
A
POWER ON  
RESET PULSE  
F
E
B
C
D
Figure 6. Commutation State Machine  
Figure 7. VCO Control  
May, 2000  
PRELIMINARY DATASHEET  