Micrel, Inc.
1b.0
KSZ8041NL
Link Up
Interrupt
1= Link Up occurred
RO/SC
RW
0
0= Link Up did not occurred
Register 1Eh – PHY Control 1
1e:15:14
LED mode
[00] =
00
LED1 : Speed
LED0 : Link/Activity
[01] =
LED1 : Activity
LED0 : Link
[10] =
Reserved
[11] =
Reserved
1e.13
Polarity
0 = Polarity is not reversed
1 = Polarity is reversed
RO
1e.12
1e.11
Reserved
RO
RO
0
0
MDI/MDI-X
State
0 = MDI
1 = MDI-X
1e:10:8
1e:7
Reserved
Remote
0 = Normal mode
RW
loopback
1 = Remote (analog) loop back is enable
1e:6:0
Reserved
Register 1Fh – PHY Control 2
1f:15
HP_MDIX
0 = Micrel Auto MDI/MDI-X mode
1 = HP Auto MDI/MDI-X mode
When Auto MDI/MDI-X is disabled,
0 = MDI Mode
RW
RW
1
0
1f:14
MDI/MDI-X
Select
Transmit on TX+/- (pins 7,6) and
Receive on RX+/- (pins 5,4)
1 = MDI-X Mode
Transmit on RX+/- (pins 5,4) and
Receive on TX+/- (pins 7,6)
1f:13
1f.12
Pairswap
Disable
1 = Disable auto MDI/MDI-X
0 = Enable auto MDI/MDI-X
RW
RO
0
0
Energy Detect
1 = Presence of signal on RX+/- analog wire
pair
0 = No signal detected on RX+/-
1 = Force link pass
1f.11
Force Link
RW
0
0 = Normal link operation
This bit bypasses the control logic and allow
transmitter to send pattern even if there is no
link.
October 2006
29
M9999-102406-1.0