Micrel, Inc.
KSZ8041NL
Register 3h – PHY Identifier 2
3.15:10
PHY ID
Number
Assigned to the 19th through 24th bits of the
Organizationally Unique Identifier (OUI).
Kendin Communication’s OUI is 0010A1 (hex)
RO
0001_01
3.9:4
3.3:0
Model Number Six bit manufacturer’s model number
RO
RO
00_0000
-
Revision
Number
Four bit manufacturer’s model number
Register 4h – Auto-Negotiation Advertisement
4.15
Next Page
1 = Next page capable
RW
0
0 = No next page capability.
4.14
4.13
Reserved
RO
0
0
Remote Fault
1 = Remote fault supported
0 = No remote fault
RW
4.12:11
4.10
Reserved
Pause
RO
00
0
1 = PAUSE function supported
0 = No PAUSE function supported
1 = T4 capable
RW
4.9
4.8
100Base-T4
RO
0
0 = No T4 capability
100Base-TX
Full-Duplex
1 = 100Mbps full-duplex capable
0 = No 100Mbps full-duplex capability
RW
Set by SPEED & DUPLEX
strapping pins.
See “Strapping Options” section
for details.
4.7
4.6
100Base-TX
Half-Duplex
1 = 100Mbps half-duplex capable
RW
RW
Set by SPEED strapping pin.
0 = No 100Mbps half-duplex capability
See “Strapping Options” section
for details.
10Base-T
1 = 10Mbps full-duplex capable
Set by DUPLEX strapping pin.
Full-Duplex
0 = No 10Mbps full-duplex capability
See “Strapping Options” section
for details.
4.5
10Base-T
Half-Duplex
1 = 10Mbps half-duplex capable
0 = No 10Mbps half-duplex capability
[00001] = IEEE 802.3
RW
RW
1
4.4:0
Selector Field
0_0001
Register 5h – Auto-Negotiation Link Partner Ability
5.15
5.14
5.13
Next Page
1 = Next page capable
RO
RO
RO
0
0
0
0 = No next page capability
1 = Link code word received from partner
0 = Link code word not yet received
1 = Remote fault detected
Acknowledge
Remote Fault
0 = No remote fault
5.12
Reserved
Pause
RO
RO
0
5.11:10
[00] = No PAUSE
00
[10] = Asymmetric PAUSE
[01] = Symmetric PAUSE
[11] = Asymmetric & Symmetric PAUSE
1 = T4 capable
5.9
100Base-T4
RO
0
0 = No T4 capability
October 2006
26
M9999-102406-1.0