WF1M32B-XXX3
AC WAVEFORMS FOR DATA# POLLING DURING EMBEDDED ALGORITHM OPERATIONS
tRC
VA
Addresses
CS#
VA
VA
tACC
tCE
tCH
tOE
OE#
WE#
tDF
tOEH
tOH
High Z
High Z
DQ7
Complement
Complement
True
Valid Data
Valid Data
DQ0–DQ6
Status Data
Status Data
True
tBUS
RY/BY#
NOTE: VA = Valid address. Illustration shows first status cycle after command sequence, last status read cycle, and array data read cycle
Microsemi Corporation reserves the right to change products or specifications without notice.
April 2016 © 2016 Microsemi Corporation. All rights reserved.
Rev. 16
9