MLX90807
Relative Integrated Pressure Sensor
3 Absolute Maximum Ratings
Parameter
Symb Min Value
ol
Max Value
Units
SupplyꢀVoltageꢀ(overvoltage)ꢀ
SupplyꢀVoltageꢀ(operating)ꢀ
SupplyꢀCurrent,ꢀIDDꢀꢀwithꢀVDDꢀ=ꢀ16ꢀVꢀ
VDDꢀ
VDDꢀ
IDDꢀ
Voutꢀ
ꢁ14ꢀ
4.5ꢀ
ꢀ
ꢁ0.5ꢀ
ꢀ
16ꢀ
5.5ꢀ
25ꢀ
Vꢀ
Vꢀ
mAꢀ
Vꢀ
OutputꢀVoltage,ꢀVoutꢀ
ꢀ
16ꢀ
Supplyꢀcurrentꢀwithꢀoutputꢀshortedꢀtoꢀ0Vꢀ..ꢀ16Vꢀ IDDꢀ
SupplyꢀCurrentꢀlimit,ꢀreverseꢀpolarityꢀ IDDꢀ
ProgrammingꢀTemperatureꢀRangeꢀ(ZAPꢀcells)ꢀ TPꢀ
OperatingꢀTemperatureꢀRangeꢀ
StorageꢀTemperatureꢀRangeꢀ
100ꢀ
160ꢀ
100ꢀ
140ꢀ
150ꢀ
2ꢀ
mAꢀ
mAꢀ
ꢀ
ꢁ20ꢀ
ꢁ40ꢀ
ꢁꢀ50ꢀ
ꢁ2ꢀ
°Cꢀ
°Cꢀ
°Cꢀ
kVꢀ
TAꢀ
TSꢀ
ꢀ
ESDꢀSensitivityꢀ(AECꢀQ100ꢀ002)ꢀ
Table 1: Absolute maximum ratings
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-
rated conditions for extended periods may affect device reliability.
4 General Electrical Specifications
DC Operating Parameters TA = -40 oC to 140 oC, VDD = 5V (unless otherwise specified)
Parameter
SupplyꢀVoltageꢀ
SupplyꢀCurrentꢀ
Symbol Test Conditions
Min Typ Max Units
Vddꢀ
Iddꢀ
Operatingꢀ
4.5ꢀ
4ꢀ
5ꢀ
7ꢀ
ꢀ
5.5ꢀ
10ꢀ
ꢀ
Vꢀ
mAꢀ
mAꢀ
Vꢀ
Vdd =ꢀ5ꢀVꢀ±ꢀ10%ꢀ,ꢀexcludingꢀoutputꢀcurrentꢀ
OutputꢀCurrentꢀCapabilityꢀ
outputꢀ@ꢀlowꢀpressureꢀ
outputꢀ@ꢀfullꢀscaleꢀpressureꢀ Voutꢀ
Ioutꢀ
Voutꢀ
Vdd =ꢀ5ꢀVꢀ
Vdd =ꢀ5ꢀVꢀ
1ꢀ
0.46ꢀ 0.5ꢀ 0.54ꢀ
4.46ꢀ 4.5ꢀ 4.54ꢀ
Vdd =ꢀ5ꢀVꢀ
Vꢀ
LowꢀClampingꢀlevelꢀ
HighꢀClampingꢀlevelꢀ
Linearityꢀerrorꢀ
Ratiometricityꢀerrorꢀ
ProgrammingꢀSupplyꢀ
ZappingꢀSupplyꢀ
ZappingꢀTemperatureꢀ
Lifetimeꢀ
Powerꢁupꢀtimeꢀ
Powerꢁupꢀtimeꢀ
Responseꢀtimeꢀ0%ꢀ/ꢀ63%ꢀꢀ Trpꢀ
Responseꢀtimeꢀꢀ10%ꢀ/ꢀ90%ꢀ Trpꢀ10ꢀ–ꢀ90
Stabilizationꢀtimeꢀ
Pressureꢀaccuracyꢀ
Voutꢀ
Voutꢀ
Voutꢀ
Voutꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
6.5ꢀ
91ꢀ
ꢁ0.5ꢀ
ꢁ0.3ꢀ
10ꢀ
15.5ꢀ
ꢁꢀ20ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
8.5ꢀ %ꢀVodꢀ
93.5ꢀ %ꢀVodꢀ
0.5ꢀ %ꢀVodꢀ
0.3ꢀ %ꢀVodꢀ
Vccꢀprog
ꢀ
10.5ꢀ
16ꢀ
100ꢀ
Vꢀ
Vꢀ
Vzap
ꢀ
Tzap
ꢀ
oCꢀ
ꢀ
ꢀ
ꢀ
ꢀ
15ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Yearꢀ
msꢀ
msꢀ
msꢀ
msꢀ
msꢀ
%ꢀFSꢀ
Tꢀ=ꢀ0ꢀoCꢀ…ꢀ85ꢀoCꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
3.5ꢀ
5ꢀ
1ꢀ
1.5ꢀ
3ꢀ
ꢀ
Tꢀ<ꢀꢀ0ꢀoCꢀorꢀTꢀ>ꢀ85ꢀoCꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Tsꢀ
ꢀ
ꢀ
1ꢀ
Table 2: Electrical specifications
3901090807
Rev 003
Page 3 of 8
Data Sheet
Feb 08