MG87FE/L2051/4051/6051
MAKE YOU WIN
Preliminary Ver 1.00
CCON: PWM-timer Control Register
Address=D8H, read/write, Power On + RESET=00XX-XXXX
7
CF
6
CR
5
-
4
-
3
-
2
-
1
-
0
-
Bit 7: CF, PWM-timer underflow Flag.
0: This flag can only be cleared by software.
1: Set by hardware when the counter rolls under. CF flags an interrupt if bit ECF in CMOD is set. CF may be set
by either hardware or software.
Bit 6: CR, PWM-timer Run control bit.
0: Must be cleared by software to turn the PWM-Timer counter off.
1: Set by software to turn the PWM-Timer counter on.
Bit 5~0: Reserved.
CACP0L: PWM-Timer L-Duty Register
Address=EAH, read/write, Power On + RESET=0000-0000
7
-
6
-
5
-
4
-
3
-
2
-
1
-
0
-
CACP0H: PWM-Timer H-Duty Register
Address=FAH, read/write, Power On + RESET=0000-0000
7
-
6
-
5
-
4
-
3
-
2
-
1
-
0
-
This document information is the intellectual property of Megawin Technology.
© Megawin Technology Co., Ltd. 2009 All rights reserved.
QP-7300-03D