MX29LV400T/B
AC CHARACTERISTICS
TA = -40oC to 85oC, VCC = 2.7V~3.6V
(TA = 0oC to 70oC, VCC = 3.3V±5% for MX29LV400T/B-55R)
Table 10. READ OPERATIONS
29LV400T/B-55R 29LV400T/B-70
29LV400T/B-90
SYMBOL PARAMETER
MIN.
MAX.
55
MIN.
MAX.
70
MIN. MAX.
UNIT CONDITIONS
tRC
tACC
tCE
Read Cycle Time (Note 1)
Address to Output Delay
CE to Output Delay
90
90
90
35
ns
55
70
ns
ns
ns
ns
ns
ns
CE=OE=VIL
OE=VIL
55
70
tOE
OE to Output Delay
25
30
CE=VIL
tDF
OE High to Output Float (Note1) 0
25
0
25
0
30
CE=VIL
tOEH
Output Enable Read
Hold Time Toggle and
Data Polling
Address to Output hold
0
0
0
10
10
10
tOH
0
0
0
ns
CE=OE=VIL
NOTE:
1. Not 100% tested.
TEST CONDITIONS:
• Input pulse levels: 0V/3.0V.
2. tDF is defined as the time at which the output achieves
the open circuit condition and data is no longer driven.
• Input rise and fall times is equal to or less than 5ns.
• Outputload:1TTLgate+100pF(Includingscopeand
jig), for29LV400T/B-90. 1TTL gate+30pF(Including
scopeandjig)for29LV400T/B-70&29LV400T/B-55R.
• Reference levels for measuring timing: 1.5V.
P/N:PM0710
REV. 1.4, NOV. 23, 2001
20