MX29LV160C T/B
Table 13. AC CHARACTERISTICS
Parameter Std Description
Test Setup All Speed Options Unit
tREADY1
RESET# PIN Low (During Automatic Algorithms)
MAX
20
us
to Read or Write (See Note)
tREADY2
RESET# PIN Low (NOT During Automatic
Algorithms) to Read or Write (See Note)
RESET# Pulse Width (During Automatic Algorithms)
RESET# HighTime Before Read (See Note)
RY/BY# Recovery Time (to CE#, OE# go low)
MAX
500
ns
tRP
tRH
tRB
MIN
MIN
MIN
500
70
0
ns
ns
ns
Note:Not 100% tested
Figure 22. RESET# TIMINGWAVEFORM
RY/BY#
CE#, OE#
RESET#
tRH
tRP
tREADY2
Reset Timing NOT during Automatic Algorithms
tREADY1
RY/BY#
tRB
CE#, OE#
RESET#
tRP
Reset Timing during Automatic Algorithms
P/N:PM1186
REV. 1.2, JAN. 19, 2006
48