 浏览型号MX29LV040CTC-70G的Datasheet PDF文件第2页浏览型号MX29LV040CTC-70G的Datasheet PDF文件第3页浏览型号MX29LV040CTC-70G的Datasheet PDF文件第4页浏览型号MX29LV040CTC-70G的Datasheet PDF文件第5页浏览型号MX29LV040CTC-70G的Datasheet PDF文件第7页浏览型号MX29LV040CTC-70G的Datasheet PDF文件第8页浏览型号MX29LV040CTC-70G的Datasheet PDF文件第9页浏览型号MX29LV040CTC-70G的Datasheet PDF文件第10页  
MX29LV040C  
TABLE 3. MX29LV040C COMMAND DEFINITIONS  
First Bus  
Bus Cycle  
Second Bus Third Bus  
Fourth Bus  
Cycle  
Fifth Bus  
Cycle  
Sixth Bus  
Cycle  
Command  
Cycle  
Cycle  
Cycle Addr Data Addr  
XXXH F0H  
RA RD  
Data Addr  
Data Addr Data Addr  
Data Addr Data  
Reset  
1
Read  
1
Read Manufacture ID  
Read Silicon ID  
Sector Protect  
Verify  
4
4
4
555H AAH 2AAH 55H 555H 90H X00H C2H  
555H AAH 2AAH 55H 555H 90H X01H 4FH  
555H AAH 2AAH 55H 555H 90H (SA) 00H  
x02H 01H  
Program  
4
6
6
1
1
1
555H AAH 2AAH 55H 555H A0H PA  
PD  
Chip Erase  
555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H  
555H 10H  
SA 30H  
Sector Erase  
Sector Erase Suspend  
Sector Erase Resume  
CFI Query  
555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H  
XXXH B0H  
XXXH 30H  
AAH 98  
Note:  
1. ADI = Address of Device identifier; A1=0, A0 = 0 for manufacturer code,A1=0, A0 = 1 for device code. A2-A18=do not care.  
(Refer to table 2)  
DDI = Data of Device identifier : C2H for manufacture code, 4FH for device code.  
X = X can be VIL or VIH  
RA=Address of memory location to be read.  
RD=Data to be read at location RA.  
2. PA = Address of memory location to be programmed.  
PD = Data to be programmed at location PA.  
SA = Address of the sector.  
3. For Sector Protect Verify operation : If read out data is 01H, it means the sector has been protected. If read out data is 00H, it  
means the sector is still not being protected.  
4. Any number of CFI data read cycle are permitted.  
P/N:PM1149  
REV. 1.3, APR. 24, 2006  
6